Télécharger Imprimer la page

DRESTER 2600 Mode D'emploi page 4

Publicité

Les langues disponibles
  • FR

Les langues disponibles

In order to maintain the high safety standard of the unit, you should ensure the following:
- that the unit is installed in the manner prescribed in this manual
- that the unit is used in the manner prescribed in this manual
- that the unit is maintained in the manner prescribed in this manual
- that only original spare parts are used
- that this manual is kept available and in legible condition close to the unit.
Always wear protective solvent-resistant gloves when handling the cleaned and still wet spray-gun.
Personnel suffering from chronic respiratory problems or allergies to solvents used must not operate the machine.
Two fire extinguishers must always be kept nearby when working with flammable solvents.
The spray-gun must be suitable for cleaning in spray-gun cleaning machines (ref. Category 2 according to EN 13463-1/2001)
If plastic drums are used, the openings should be wiped with a damp cloth to avoid static electricity
Weekly:
-
Clean the washing compartment's working platform (perforated pressing) and the bottom of the washing compartment.
When changing drums:
-
Check and if necessary clean the strainer on the suction line for circulating solvent.
Hedson Technologies AB will replace all faulty parts on the DRESTER 2600 with new parts in accordance with the "Warranty
Terms for Hedson Technologies AB". This warranty only remains valid if the machine is used in the prescribed manner, and it
does not cover the cost of repairs. Always state the machine's serial number and year of manufacture if making a claim under
warranty. These can be found on the machine's silver-coloured rating plate. The warranty terms may vary from country to
country. The importer can provide you with details.
Manufacturer:
Type of machine:
Liquid volume of machine:
Permitted solvents:
Compressed air needed:
Extraction capacity:
Pump capacity:
Solvent pressure:
Weight:
Overall dimensions:
Extractor diameter:
Sound pressure level:
SAFETY INFORMATION
SERVICE
WARRANTY
TECHNICAL DATA
HEDSON TECHNOLOGIES AB
Hammarvägen 4
SE-232 37 Arlöv
Sweden
 +46-40-53 42 00
DRESTER 2600
12.5 + 12,5 litres
See section "Permitted Solvents"
5–12 bar (80-180 psi), 250 l/min (9 cfm)
3
140 m
/hour (82 cfm) (with a 15 m extension)
3
180 m
/hour (106 cfm) (with a 5 m extension)
10 l/minute,
2 bar (30 psi)
30 kg
Height: 990 mm (39"), max. diameter: 563 mm (22"), width: 700 mm (27,5")
125 mm (5")
<70 dB(A)
4

Publicité

loading