USER'S MANUAL FOR TYPE LB POWER UNIT

1. Introduction

Read this manual completely before you install and put this product into use.
Follow the instructions set out in this manual to ensure proper operation of the product and to
be able to invoke guarantee.
The guarantee terms are stated in the General Conditions for the Sale and Delivery of Products
and/or Performance of Activities by SIMCO (Nederland) B.V.

2. Safety

 The power unit is only intended as a power source for Simco-Ion ionisation equipment.
 Electrical installation, maintenance and repairs shall be made by a skilled electrical engineer.
 When carrying out work on the equipment: de-energise the equipment.
 If changes, adjustments, etc. have been made without prior consent in writing, or if no original
parts have been used for repairs, CE approval for the equipment will be withdrawn and the
equipment will no longer be under guarantee.
 Make sure that the equipment is properly earthed.
Earthing is needed to ensure proper operation and to avoid electrical shocks upon contact.

3. Use and operation

The power unit serves as a power source for Simco-Ion ionisation equipment.
The power unit comprises two transformers which are opposite in phase. If one transformer is in
the positive sinusoidal half wave of the alternating voltage, the other transformer is in the
negative sinusoidal half wave.
This simultaneously produces positive and negative ions on the connected equipment, so the
material is neutralised even at high material speeds (upwards of 300 m/min).
The neon lamp gives an indication of the high voltage. The transformer is short-circuit-proof.
The maximum output current (short-circuit current) is restricted in the transformer.

4. Technical specifications

Connected loads:
Secondary voltage:
Secondary current:
Operating conditions:
Ambient temperature:
Sealing:
Max. load per transformer:
Optionals:
LB-Unit_UM_9752083410_NL_D_GB_F_V2_0
See rating plate
See rating plate
2.5 mA max. (per transformer)
Industrial
max. 50 °C
IP-54
approx. 15-m bar, including shielded cable
Printed circuit board with:
- Balancing; HV alarm and remote control
(not wireless).
-Detection output voltage
GB
25