Zone Masking Menu - Videotec ULISSE PLUS Manuel D'instructions

Unité de positionnement de grandes dimensions
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

05. Text: Modifies the text which is displayed when
moving within the zone.
ZONE TITLING
------------------------
1>NR.
:
2 ENAB.:
3 START: +
4 STOP : +
5 TEXT : ZONE 1
Fig. 60
Example: To enable titling of zone 1 when the device
is between +15° and +45°, it is necessary to:
• Enable area titling by setting Y as the value of
Enabling.
• Set 1 as the value of parameter Nr.
• Set +015.00 as the value of parameter Start.
• Set +045.00 as the value of parameter Stop.
• If necessary, edit the displayed text by selecting
Text.
j
Setting the Start and Stop values of the
menu to zero will disable text display. If
there are overlapping areas, the area with
the lowest number will prevail.
To define zones proceed in a clockwise
j
direction, as shown in the figure.
Stop2=225°
270°
180°
Start2=170°
Fig. 61
1
N
0.00
0.00
Start1=15°
Stop1=45°
90°

9.6.3.2 Zone Masking Menu

This function allows setting up to eight masks
(variable dimension) with titling option.
01. Number: Selects the mask to modify.
02. Enabling: Enables masking of the relative zone.
03. Start: Sets the starting position of the mask.
04. Stop: Sets the stop position of the mask.
05. Text: Changes the text displayed when the mask
is enabled.
ZONE MASKING
------------------------
1>NR
:
2 ENAB.:
3 START: +
4 STOP : +
5 TEXT : MASK 1
Fig. 62
1
N
0.00
0.00
29

Publicité

Table des Matières
loading

Table des Matières