How to change airfl ow direction
The DISCHARGE GRILLE is installed at the factory to provide 45˚
upward airfl ow into the room. (Direction 1 in Figure 5). If a vertical
airfl ow is desired (Direction 2), the direction can be changed by rotating
the DISCHARGE GRILLE.
Unplug the air conditioner.
Remove the DISCHARGE GRILLE RETAINER attached with one
screw in the right side of the grille.
Remove the DISCHARGE GRILLE from the retaining slots near the
CONTROLS, and rotate the grille as shown in Figure 5.
Reinstall the DISCHARGE GRILLE by placing it in its retaining slots.
Reattach the DIS CHARGE GRILLE RE TAIN ER with the retaining
screw. The unit is now ready to operate.

How to cover inner weather panel holes

Two beige plugs are included in the plastic bag taped to the WallMaster
chassis. These plugs may be used to cover the two holes left after
removing the inner weather panel (see Figure 5). The plugs must be
attached before the DECORATIVE FRONT frame is installed.

Electrical requirements

IMPORTANT: Before you begin the actual installation of your air
conditioner, check local elec tri cal codes and the information below.
Your air conditioner must be connected to a power supply with the same
AC voltage and hertz rating as marked on the nameplate located on
Figure 5
Airflow
Decorative
Front
Return
Air Grille
2
2
2
1
1
1
920-007-14
Electrical Shock Hazard
Use correct circuit protection.
Failure to follow these instructions can result in
death, fire, or electrical shock.
the chassis. Only alternating current (AC) can be used. Consult pages
3 and 7 for the correct type of receptacle for your model.
An overloaded circuit will invariably cause malfunction or failure of an
air conditioner, therefore, it is extremely im por tant that the electrical
power and the wiring is adequate. Consult your dealer or power
company if in doubt.
CIRCUIT PROTECTION - Before installing or relocating your
Friedrich Room Air Conditioner, check the amp rating of the circuit
breaker or "TIME-DELAY" fuse. Refer to the nameplate located on
the air conditioner chassis to de ter mine the correct fuse or circuit
breaker am per age for your model. The rating MUST NOT exceed
the value stated on the nameplate. If the air conditioner is connected
to a circuit protected by a fuse, a "TIME-DELAY" fuse must be
used due to the momentary high current demands when your air
conditioner is started.
WSC
Sleeve
Discharge
Grille
WARNING
1" Diameter Plug
7