Check the door switch: close the steam room's door. Turn the
control console on. Set the temperature. Turn the heating on.
Contactors must switch on. Open the door. Contactors must switch
off in 5-10 seconds. Close the door. Contactors must switch on again.
•
Check the temperature sensor:
•
Install the protection. Switch the power off from the sauna's
switchboard for quarter of minute and then on again. The
control console must have turned off and when it is turned
on, it must show the current temperature.
•
The temperature is renewed periodically, one degree at a
time – therefore it may take some time to reach the actual
temperature reading.
•
Set the desired temperature to 50 °C. Turn the sauna on.
Check that desired temperature is maintained. Turn the
heating off.
•
Set the desired temperature. Turn the heating on. Check that
the temperature is achieved and maintained.
OPERATION MANUAL
•
To turn on the control panel, start or end the heating, press the
button once briefly.
•
During heating, the heating icon
temperature value.
•
If the symbol
connection has been turned on. The sauna will not be connected
to the network before it is connected to the app.
•
The control console is connected to the network and ready for
use, if
appears on the status line.
•
The signal strength of the cellular network is indicated by the
filled bars.
•
The screen is always active during heating.
•
Using the sauna from the control panel you can choose between
heating times of 3, 6 hours for private saunas, 12 hours for
semi-public saunas and 18 hours for public saunas from the
appears on the status line, it means that GSM
will appear above the
11