User Calibration - Snap-On EEWB330B Mode D'emploi

L'équilibreuse de roues par ordinateur
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Figure 30a
Figure 30b
Figure 30d
Figure 30e
Figure 30f
Figure 30g

7.0 USER CALIBRATION

+
The EEWB330B Balancer features a User Calibration
which requires only a few minutes to complete. The
operator can electronically calibrate the rotating masses
on the machine; which is called User Calibration.
Perform this procedure when the balancer has been
moved, disturbed, or whenever accuracy is questioned.
If the calibration process fails a service technician must
be called to perform a complete calibration.
A calibration run requires little more time than a regu-
lar balance run.
Figure 30c
Procedure;
— Balance a wheel (15" x 6,5"), as a NORMAL weight
— Press the "MODE" key and the "FINE" key together
The initial display reads "C 14", See Figure 30b.
— Press "ENTER" once to initiate procedure.
The display shows "CAL 1". See Figure 30c.
— Remove any cones or adapters from the shaft. See
When compete, the display shows "CAL 2". See Figure 30e.
— Mount the User Calibration Weight, refer to Figure
— After a few seconds the display equals C ---, Figure 30g.
The User Calibration was performed correctly.
Any (operator) error causes the program to exit. Un-
screw the Calibration weight from the fl ange and put it
back in its designated place for safe keeping.
EEWB330B
mode, to less than 5 grams per plane.
for 5-7 seconds. See Figure 30a.
Figure 30d.
Note: Continue the spin until the unit beeps.
30f. Spin the shaft.
21