Temp Sensor
Temperature Sen-
sor disconnected
E2 Unconnected
PCB too hot E3
Main board too
hot
Time remain E4
Insufficient time
Temp Over heat
Heating pro-
E5
tection due to
over-temperature
Heat Fail E6
Heating process
fail
Tip over E7
Tip over alert
Sub PCB uncon-
Sub-PCB dis-
nected E8
connected
Illegal Card
Machine locked
because the RFID
Machine Locked
card is illegal or a
copy
SPECIFICATIONS
Power supply .......................................................................................... 200-240V~ 50/60Hz
Consumption .................................................................................................................... 600W
Heating time .............................................................................................................. 5 minutes
Granule consumption .......................................................................................... 20-25g/min.
Height of spark fountain ............................................Adjustable from 1.5 - 5m in 10 steps
Density ........................................................................................................................ 30-100%
Max. output duration. ............................................................................................. 30 seconds
Powder tank capacity ....................................................................................................... 150g
Weight ................................................................................................................................... 8kg
Dimensions .............................................................................................. 215 x 250 x 330mm
IMPORTANT NOTE: Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local
authorities or your dealer about the way to proceed.
1. Check wire connection of the temperature sensor
2. Replace temperature sensor
3. Replace main board
Stop operating the machine until the main board tempe-
rature has turned to normal
Please scan new RFID card
Stop operating the machine until temperature returns to
normal. Alert will clear off automatically
1. Inspect wire connection of heating board
2. Replace heating coil
3. Replace heating board
Machine will activate tip over protection if the angle is
more than 45 degrees. The alert will clear off automati-
cally once the machine is back to normal position.
1. Check wire connection of Sub-PCB
2. Replace sub-PCB
3. Replace main board
The use of an illegal or copied RFID card will lock the ma-
chine. In that case, the seller will stop providing warranty
and after-sales service. To unlock the machine, please
contact your seller.