The remote control allows to select among 4 height levels.
INSTALLING THE BATTERY IN THE REMOTE CONTROL
• Place the remote face down on a flat surface.
• Push the compartment cover into the direction of the arrow to slide the battery compartment
open.
• Remove the old battery and install the new one (LR23A 12V) with the correct polarity.
• Gently slide the battery compartment closed. It locks automatically.
RECOMMENDATIONS FOR BATTERIES
This symbol indicates that used batteries should not be disposed of with household waste but deposed correctly in accordance with
your local regulations..
Batteries shall not be exposed to excessive heat such as sunshine, fire or the like.
When the internal batteries are not to be used, remove them to avoid damage caused by battery leakage or corrosion.
: Danger of explosion if battery is incorrectly placed. Only replace by the same or equivalent type.
ATTENTION
:Do not swallow the battery. Danger of chemical burns. Keep new and old batteries out of the reach of children.
WARNING
If the battery compartment doesn't close properly, stop using the product and keep it out of the reach of children.
If you are in doubt whether the batteries have been swallowed or introduced into any other part of the body, contact immediately a doctor.
CLEAR MATERIAL
The machine offers a cleaning function of heated but not sparked consumables to avoid residues
in the heating chamber and blocking of the machine.
Use the cleaning function of channel 2, DMX values 56-200.
Clear material after each show.
CLEANING
• After the clearing process, clean the machine to extend its life time.
• Turn off power
• Unplug the mains and the DMX cables.
• Remove dust and debris from the machine with a damp cloth.
MAINTENANCE
After a period of use, clean the nozzle to remove eventual residues of consumables.
FAILURE HANDLING
Error Code
Description
System Error
E0 storage fail
Motor protect
E1 M1
Motor protect
E2 M2
Motor protect
E3 M3
EN
8
Solution
System error:
Replace main board
storage fail
Blower motor
1. Restart machine to clear alerts, stop operating for 15
protection / dis-
connected
2. Check wire connection of the motor
3. Replace motor
4. Replace main board
Shaft motor
1. Shaft motor clog (perform Clear material function
protection / dis-
connected
2. Check wire connection of the motor
3. Replace motor
4. Replace main board
Hopper motor
1. Hopper motor clog (perform Clear material function
protection / dis-
connected
2. Check wire connection of the motor
3. Replace motor
4. Replace main board
minutes until temperature has returned to normal.
manually)
manually)
© Copyright LOTRONIC 2022