INSTALLATION OF THE MACHINE
Install the machine on a fi rm, level ground. The maximum tilt angle shall not exceed 15 degrees.
= 0°
≤ 15°
≤ 15°
Install the machine on a truss via the supplied accessories.
FILLING IN THE GRANULATE
Please use our LARGE size granulate for spark fountains of 3-5m height
Open the lid
(order code: SPARK-POWDER-LARGE).
1. Open the vacuum package of granules and fi ll them into the granule
receptacle on top of the machine. The maximum capacity is 150g.
2. DO NOT fi ll granules into the output nozzle!
3. Close the lid securely after fi lling.
OPERATION
CONNECTION
Plug in the supplied mains lead into the POWER IN socket of the machine. If you wish to dai-
sy-chain several machines, plug another power lead into the POWER OUT socket and the other
end into the POWER IN connector of the following machine.
Plug a 5-pin DMX cable into the DMX IN socket and the other end into the DMX OUT connector of
your DMX controller. If you want to connect another machine, connect the DMX OUT connector to
the DMX IN connector of the following machine.
Connect a DMX512 controller via a DMX signal cable to the DMX IN connector.
DMX connector confi guration
DMX terminators reduce signal errors. To avoid signal transmission problems and interference, it is
always advisable to connect a DMX signal terminator between pin 2 and 3 of the last unit.
POWER LINK
You can power up to 4 units via the POWER IN/POWER OUT connectors from one single mains
outlet. Connect a power cable from the POWER OUT connector of the 1st unit to the POWER IN
connector of the second unit, etc.
© Copyright LOTRONIC 2022