Display
Parameter
Value
Assistance request: This function allows you to set the number of cycles to be run before maintenance begins. For
information about the operation of this function, see the next paragraph.
0
Assistance request disabled
1
Assistance request after 10,000 cycles
2
Assistance request after 20,000 cycles
3
Assistance request after 30,000 cycles
4
Assistance request after 40,000 cycles
U
5
Assistance request after 50,000 cycles
6
Assistance request after 60,000 cycles
7
Assistance request after 70,000 cycles
8
Assistance request after 80,000 cycles
9
Assistance request after 90,000 cycles
Cycle counter: The number of cycles, in thousands, performed by the automated system is displayed. For example, if
"15" is shown, this means that the automated system has performed 15,000 cycles. For more detailed information, see
the next paragraph.
00
Indicates the number of cycles performed by the automated system
The indicated conditions are the control unit's default. Make a note of the adjustments carried out in order
to restore them if the control unit is replaced.
You can access and modify the operation parameters only when the automated system is closed in rest
position - the display must indicate value "– –".
Whenever you access display / modification of the operating parameters, at the next OPEN impulse, the control
unit runs a programming procedure, recalculating the opening and closing time. The automated system does
not perform the slow-downs during the first opening.
10.1. ASSISTANCE REQUEST
This function allows you to set the number of cycles to be run before a technical assistance job. When the number of
set cycles is reached, this is signalled by about 5 seconds flashing, at the end of every closure manoeuvre and the
control unit's display indicates value "AS". The resetting of the number of cycles must be done manually.
This function signals but does not prevent normal operation of the automated system.
The screen after parameter "U" shows the number of cycles in thousands, e.g., if you read "05"this means that the
automated system has performed 5,000 cycles. The maximum number of cycles the control unit can count is 99,000
- when this value is reached, the count stops and must be manually reset.
10.1.1. R
ESETTING THE NUMBER OF CYCLES
This is the procedure for resetting the number of cycles:
1.
Make sure that the display shows value "– –".
2.
Press and hold down push-button P2 until the first parameter "A" appears on the display.
Scroll all the operating parameters until the number of performed cycles is shown.
3.
4.
Simultaneously press push-buttons P1 and P2 for about 10 seconds.
5.
When value "00" appears on the display, cancellation has been done.
6.
Press key P2 again, and wait for 60 seconds, to return to normal operation.
7.
Give an OPEN impulse to perform a cycle.
Follow the procedure below to start up the system for the first time:
1.
Power up the automated system and check that all the LEDs are in the situation described in paragraph 8.
2.
Make sure that the display shows value "– –".
3.
Adjust the operating parameters, as described in paragraph 10.
4.
When you have finished adjusting the parameters, give an OPEN/CLOSE impulse, using any impulse generator
connected to this input, or the radio control if already memory-stored.
5.
The control unit starts an OPENING manoeuvre, until the opening travel limit device is reached and the display
shows value "OP".
During this stage, the control unit does not perform any slow-down.
If the automated system does not move and the display shows value "OP", this means that it is performing a
closing manoeuvre and the motor wires must be reversed. Give a RESET command by pressing push-button
P5, cut power and reverse the wires connected to terminals 6 & 8. Restore the power supply and resume from
point 4.
Description
11. START-UP
25