Genius LYNX 06/230V Mode D'emploi page 26

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
Display
Parameter
Value
Condo function: If this function is activated, during the opening manoeuvre, the automated system ignores successive
impulses both of OPEN/CLOSE and of CLOSE until the system has completed the opening stage.
0
Condo function disabled
E
1
Condo Function Activated
Slow-down percentage: This parameter is used to select the length of the slowed down section before the travel limit
device intervenes. The length of the slowed down section is calculated as a percentage of the opening and closure
times.
0
No slow-down
1
Slow-down is 30% of the stroke
H
2
Slow-down is 40% of the stroke
3
Slow-down is 50% of the stroke
Heating function: If you activate this function, the control unit feeds the motor at a very low voltage in order to maintain
the motor at a temperature above ambient temperature. This function is active only when the automated system is
closed at rest, and if an OPEN command is sent, the function is interrupted.
0
Function disabled
1
Function enabled – a heating cycle every 5 minutes
M
2
Function enabled – a heating cycle every 15 minutes
3
Function enabled – a heating cycle every 30 minutes
4
Function enabled – a heating cycle every 40 minutes
Immediate closure: This function is active only when the function can only be activated combined with function logics
with Automatic re-closure, Automatic, Step-by-step automatic or Condo, and with the safety devices active only in
closure "y0".
With this function activated, and while the automated system is open in pause mode, when a change in the state of
the safety devices' is detected, e.g. when transiting in front of the photocells, the automated system closes immediately
without waiting for the pause time to elapse.
0
Immediate closure disabled
o
1
Immediate closure activated, but only with "y0"
Immediate closure / Timer: This function enables you to activate immediate closure or automation shut-down with
the OPEN/CLOSE command. The function can be activated only when combined with function logics with automatic
re-closure, Automatic logic, Automatic step-by-step logic, or Condo.
Immediate closure activated: with the automated system open in pause mode, an impulse of
0
the OPEN/CLOSE command causes the automated system to close immediately without waiting
for the pause time to elapse.
Timer function activated: If you activate this function, with the automated system open in pause
P
state, at every OPEN/CLOSE command, the control unit restarts the pause time count. If the
1
command is maintained active, the control unit stops the pause time count and the automated
system remains idle. The control unit resumes the pause time count only when the OPEN/CLOSE
command is released.
Soft start: This function enables a softer start of the automated system.
0
Soft start function disabled
r
1
Soft start function enabled
Operation of safety devices: This parameter enables you to select the intervention method of the safety devices
connected to the control unit.
0
Safety devices active only during closure of the automated system
y
1
Safety devices active during the closure and opening of the automated system
Description
24

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Lynx 07/115vLynx 06 230vLynx 06 115v

Table des Matières