Design of wireless range
The radio signal is attenuated on the way from the transmitter to
the receiver. In addition, the radio signal is attenuated/influenced by
obstacles. The degree of attenuation depends on the material of the
obstacle. The following tables serve as a guide.
Penetration of radio signals:
Material
wood, gypsum, glas uncoated
brick stone, press boards
armoured concrete
metal, aluminium lamination, water
Typical ranges:
Place of use
in free field (SW868/915/917)
in free field (SW922)
indoors (SW868/915/917)
indoors (SW922)
Start-up and operation mode
Requirements:
- Connect cable for supply voltage. External fuse necessary (see
»Switching example«).
- Pay attention to contact names and circuit diagrams.
- The LED shows the operating states. If the wireless actor and the
LED are both switched on, then the device is ready for use.
Switching the relays
Switching the relays: Set the relays as described in the »Description
of interface« in paragraph »RECORD.RELAIS_SWITCH« (see RF RxT
SW868/915/917/922-NET, »Description of interface«, section »Data-
Message«, download from www.steute.com). The relays are always
switched during wakeup time of RF UBR SW868/915/917/922-NET.
Set wakeup time: Set wakeup time as described in the »Description
of interface« in paragraph »RECORD.WAKEUP« (see RF RxT SW868/
915/917/922-NET, »Description of interface«, section »DataMessage«,
download from www.steute.com).
For example: »0x01« for relays switching once a minute.
Operation mode
Operational, not taught in
Operational, taught in
Push-button actuated, telegram sent
Safety
Do not use the device in connection with other devices whose direct or
indirect purpose is to ensure life or health, or whose operation may
pose a threat to humans, animals or material assets.
N.B.
The described products have been developed in order to assume func-
tions as part of an entire plant or machine. It is the responsibility of the
manufacturer of a plant or machine to guarantee the correct general
function. We reserve the right to make design changes in line with
technological progress. Reconstruction and alterations to the device
Penetration
are not allowed. steute does not assume any liability for recommenda-
90...100 %
tions made or implied by this description. New claims for guarantee,
65...95 %
warranty or liability cannot be derived from this document beyond the
general terms and conditions of delivery.
10...90 %
0...10 %
Cleaning
Wireless range (approx.)
450 m
150 m
Clean enclosure on the outside only. Clean enclosure with household
40 m
cleaning agents. Do not use any compressed air to clean.
20 m
Maintenance and repair
We recommend regular maintenance as follows:
1. Removal of all dirt particles.
LED
Disposal
lights up red
- Observe national, local and legal regulations concerning disposal.
- Recycle each material separately.
lights up green
flashes orange
4 / 28
=
DANGER
Live parts. Electric shock hazard! When cleaning:
observe IP degree of protection.
=
DANGER
Live parts. Electric shock hazard! Do not repair
defective or damaged devices. Replace them.
Alternative: Repair of defective device by trained
personnel in agreement with steute and with steute
spare parts.
=
DANGER
Live parts. Electric shock hazard! Risk of burns!
Do not rebuild or modify the device in any way.
=
DANGER
Live parts. Electric shock hazard! Open device only
while it is in zero potential state.