13. TIPS FOR A SUCCESSFUL INSTALLATION
13.1 High speed movements
PROBLEM
The motor stops for the effort during the movements
It is easy to stop the automation during the movements counteracting the movement
The door moves slowly despite having set an high speed
The motor stops and the control board shows FAULT on the display or 10 s of fast blinking
13.2 Low speed movements (slowing down)
PROBLEM
The motor stops for the effort during the movements
It is easy to stop the automation during the movements counteracting the movement
The door moves slowly despite having set an high speed
Power supply
Photocells power supply
Accessories power supply
Motor output
Flashing light output
Courtesy light output
Electrobrake or electric lock output
Clean contact output NOT supplied.
PROGRAMMING SUN REMOTE CONTROLS
1. Press and hold PROG for at least 2 s. DL1 will flash red for 10 s.
2. During this time, just press one of the buttons on the SUN remote control to memorize
the code.
ch: A
TECHNICAL FEATURES
230 Vac ±15% 50/60 Hz 1-phase
24 Vdc 3 W MAX
24 Vac 3 W MAX
230 Vac 3-phase 1,5 KW MAX (current limited to 10 A) cosφ > 0.8
230 Vac 60 W MAX for fixed light, without self-blinking.
230 Vac 100 W MAX
230 Vac 5 A Max, 30 Vdc 5 A Max
ch: B
Raise the torque supplied to the motor until problem is solved
High Torque OP, High Torque CL
Lower the speed of the motor until problem is solved
High Speed OP, High Speed CL
Lower the torque supplied to the motor until problem is solved
High Torque OP, High Torque CL
Lower the speed of the motor until problem is solved
High Speed OP, High Speed CL
Raise the torque supplied to the motor until problem is solved
Low Torque OP, Low Torque CL
Lower the speed of the motor until problem is solved
Low Speed OP, Low Speed CL