iNSTallaTiON

installation
Flow rate
f Ensure that the flow rate for switching on the appliance is
achieved.
f If the required flow rate is not achieved when the draw-off
valve is fully open, increase the water line pressure.
10. Installation
factory settings
Internal anti-scalding protection in °C
Connected load in kW
Standard installation
Electrical connection from below, installa-
tion on finished walls from below
Water connection, installation on finished
walls
For further installation options, see chapter "Alternative instal-
lation methods".

10.1 Standard installation on finished walls

Opening the appliance
f Open the appliance by undoing the screw and lifting up the
appliance cover.
Preparing the power cable
A
f Prepare the power cable.
Position on finished walls
Bottom, centre
Bottom, left side of appliance
Bottom, right side of appliance
Top, right side of appliance
Position on unfinished walls Dimension a
Bottom
Top
www.stiebel-eltron.com
DCE-X 6/8
DCE-X 10/12
Premium
Premium
60
@ 220 V
8.0
@ 230 V
8.7
@ 240 V
9.6
DCE-X 6/8
DCE-X 10/12
Premium
Premium
x
x
B
Dimension a
Dimension B
30
120
20
90
20
90
20
80
Dimension B
20
90
20
80
Preparation
5
60
12.0
13.1
14.3
1 Strainer
2 O-rings
3 45° twin nipple
4 Flat gaskets
x
5 Locking screws
6 Cable grommet
x
f Undo the locking screws.
f Push/break out the required apertures where marked on the
appliance back panel for the power cable and twin nipples.
Use a suitable flat tool when doing so. Deburr any sharp
edges with a file.
f Remove the transport protection plugs from the water con-
nection pipes.
f Cut a hole in the cable grommet to fit the selected connecting
cable. Fit the cable grommet.
f Fit the O-rings into the groove on the twin nipples.
f Push the twin nipples into the apertures in the appliance
back panel and fit them to the appliance connection pipes
using flat gaskets (torque 8 Nm).
f Secure the twin nipples with the locking screws.
f Insert the strainer in the twin nipple of the cold water
connection.
Installing the appliance
f Push/break out the lower slots (175 mm apart) in the back
panel for securing the appliance (for positions, see chapter
"Specification / Dimensions and connections"). The upper two
fixing holes are already open.
f Mark out the 4 drilling positions with reference to the appli-
ance back panel.
f Drill the holes and secure the appliance using suitable fixing
materials (screws and rawl plugs are not part of the standard
delivery): Countersunk screw, Ø 4.5 mm, max. diameter of
screw-head 9 mm.
4
3
2
1
6
DCE-X Premium |