G G
B B
LOW SPEED Trimmer to select the gate leaf low speed in
approaching.
FOR FAST VERSION code BA03221 - BA03177:
4 - After 1 sec. and within 5 sec. of continuous work, both in
closing or opening, the electronic clutch intervenes
automatically. Adjust the force of the electronic clutch by
turning the appropriate trimmer TORQUE.
5 - After 5 sec. of continuous work, both in closing or opening, the
deceleration is automatically activated (if DIP8 OFF). Adjust the
low speed during the deceleration by turning the appropriate
trimmer LOW SPEED.
6 - Press and hold the PROG button to close completely the gate. Turn
DIP1 to OFF, the RED led DL1 will stop blinking.
During Point C procedure, safety devices (photocells and safety
strip) are not active.
(#) In Point D and Point E procedures, all the safety devices (photocells
and safety strip) will be active, so they must be properly installed and
connected to the control board. Any changing of the safety devices
input state, will stop the Point D and Point E procedure that must be
repeated from the beginning.
POINT D
- PROGRAMMING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, LED DL1 starts blinking
3 - Press PROG. Button, motor opens.
4 - Once reached the open position, the open limit switch will cut out
motor and the gate travelling will be stored. The gap of time between
now (stop of motor) and the next pressing of the PROG. button (see
step 5 below) will be then stored as waiting time for Automatic
Closing feature.
5 - Press PROG. button, gate closes and the Automatic Closing time
is stored (see DIP3 function to enable or disable the Automatic
Closing feature).
6 - The LED DL1 will turn OFF, signalling exit from the Point D
procedure.
Closing of the gate will be carried out at normal speed and only on
approaching total closing at low speed (depending on the
adjustment of LOW SPEED trimmer).
7 - When the gate leaf reaches the close limit switch plate, the motor
stops.
8 - Turn DIP2 to OFF position.
During Point D procedure, safety devices (photocells and safety
strip) are active.
POINT E
- PROGRAMMING OF PEDESTRIAN OPENING (#)
1 - The gate must be fully closed.
2 - Turn DIP2 to ON position, the LED DL1 starts blinking quickly
3 - Immediately, turn also DIP1 to ON position, the LED DL1 starts
blinking slowly
4 - Press the pedestrian pushbutton PED. BUTT, the gate opens
5 - When the gate leaf is opened enough for the pedestrian crossing,
press the pedestrian pushbutton PED. BUTT to stop the travel
(thus defining the opening stroke of the motor). The gap of time
between now (stop of the motor) and the next pressing of the
PROG. button (see point 6 below) will be stored as waiting time for
Pedestrian Automatic Closing feature.
6 - Press the pedestrian pushbutton PED. BUTT, gate closes and
the Pedestrian Automatic Closing time is stored (see DIP3 function
to enable or disable the Automatic Closing feature).
7 - Turn DIP1 to OFF position.
8 - Turn DIP2 to OFF position.
During Point E procedure, the safety devices (photocells and
safety strip) are active.
POINT F
- RADIO CODE STORING (ONLY FOR CRX)
(MAX 60 CODES)
1 - Turn DIP1 to ON position, the LED DL1 starts blinking quickly.
2 - Immediately, turn also DIP2 to ON position, the LED DL1 starts
blinking slowly.
Each code must be programmed within 10 seconds.
3 - Press one of the buttons on the remote control (usually channel
A). If the remote control is stored correctly green LED L10 (on the
K-CRX control board) emits a flash. The 10 seconds' time within
storing radio code is automatically renewed to allow the storing of
the next remote control.
4 - To end radio code storing either press PROG. button or let 10
seconds pass. The LED DL1 will turn OFF.
5 - Turn DIP1 to OFF position.
6 - Turn DIP2 to OFF position.
POINT G
- RADIO CODE ERASING (only for CRX)
1 - Turn DIP1 to ON position, the LED DL1 starts blinking quickly.
2 - Immediately, turn also DIP2 to ON position, the LED DL1 starts
blinking slowly.
Code erasing must be carried out within 10 seconds.
3 - Press the PROG. button and hold it for 5 seconds, the total
memory erasing will be indicated by two flashes of green LED DL2.
LED DL1 will blink for 10 seconds and it will be possible to store new
radio codes following the Point E procedure described above.
4 - To end radio code storing either press PROG. button or let 10
seconds pass.
5 - Turn DIP1 to OFF position.
6 - Turn DIP2 to OFF position.
POINT H
- RADIO CODE FULL MEMORY TEST (only for
CRX)
1 - Turn DIP1 to ON position, the LED DL1 starts blinking quickly.
2 - Immediately, turn also DIP2 to ON position, the LED DL1 starts
blinking slowly.
If the Green LED DL2 flashes six times, it means that the radio code
memory is FULL (maximum codes to be stored 60).
3 - Turn DIP1 to OFF position.
4 - Turn DIP2 to OFF position.
F
UNCTIONING OF CONTROL ACCESSORIES
STEP BY STEP or AUTOMATIC commands
(K BUTT button, PED BUTT button, RADIO REMOTE button)
DIP 6 - ON The K BUTT,
the PED BUTT button, the RADIO
REMOTE buttons perform the cyclic command open-
stop-close-open-stop-etc.
DIP 6 - OFF The K BUTT,
the PED BUTT button, the RADIO
REMOTE buttons perform:
- the open command, if pressed with the gate
completely closed
- the close command, if pressed with the gate
completely opened
- no effect, if pressed during the gate opening
- the gate re-open, if pressed while the gate is closing
The K BUTT opens the gate completely, whereas the PED BUTT
opens the gate partially as described in Point D.
CLOCK FUNCTION (available ONLY with DIP 6 OFF)
The Clock Function permits to keep the gate opened even if, for
example, the Automatic Closing is enabled (DIP3 ON) or somebody
commands the gate closing. It is useful during rush hours, when
traffic is heavy and the flow is slow (e.g. entrance/exit of
employees, emergencies in residential areas or car parks and,
temporarily, for removal vans) and it's necessary to keep the gate
opened.
It can be done by connecting a switch and/or a daily/weekly clock
either in parallel to the K BUTT button or instead of the K BUTT
button. When the control board receives this command, the gate
will open and by keeping this contact closed for all the time of the
gate opening, the Clock Function is automatically activated. In fact,
once reached the open position, the gate will remain opened and all
of the control board functions are blocked. Only when K BUTT
contact is released, the control board functions are re-activated and
the Automatic Closing restarts (if enabled) doing the countdown to