Technical Specifications
Scale Indicator:
Input signal range:
Sensitivity:
Internal Resolution:
Display Resolution:
System Linearity:
Load Cell excitation Voltage:
Load cells:
Quantity: 4 pcs
Capacity (per cell): 1000kg
Sensitivity: 2.5±0.5mV/V
Input resistant: 400±10Ω
Output resistant: 352±2Ω
Temperature:
o
o
Operation: 5
C - 35
C
o
o
Storage:
10
C - 70
C
Humidity: ≤95%RH (no condensation)
Power:
Battery: 6V4AH lead acid battery, 30 hours continuous usage.
When the voltage of battery is below 5.7V, the "Low Bat" annunciator will be lighted, plug in AC adapter to charge
the battery. When "Lo.bAt" and actual weight is displayed alternately, this indicates the voltage of battery is below
5.5V and the scale will be turned off in two minutes automatically.
Connection Information
Loadcell socket
RS232
0mV ~ +30mV
>0.2uV/grad
Approximately 520,000 counts
Can be selected between 500-100,000
Within 0.01% of FS
+5 V
(MAX current: 85mA)
DC
Power/Adapter Socket