Télécharger Imprimer la page

Brecknell PS3000 Mode D'emploi page 14

Publicité

Les langues disponibles

Les langues disponibles

Config
Available
Menu
Settings
P7
00-31
P8
0, 1, 2
P9
0-5
P10
0, 1
You may choose to configure your scale for a higher resolution. The factory does not recommend increasing the
resolution above 3,000 divisions for a stable weight reading. Certain environments may cause the scale to be
unstable at factory settings, reduce the number of division settings to increase your stability.
Calibration settings when configuring an SBI 100 Indicator to a remote base
If you are configuring the SBI 100 Indicator to be used with a scale other than the PS3000 base, you will need to
alter the configuration setting in P7- P10 manually.
In order to configure the indicator, follow the steps defined below:
1. Determine the full capacity of your scale. Example: 3000 pounds
2. Determine the displayed division of your scale. Example: 1 pound (this is your P8, P9, and P10 setting)
3. Divide the capacity by the displayed division to determine the displayed resolution of your scale. Example:
3000/1 = 3000 (this is your P7 setting)
You are now able to configure P7 – P10 as follows.
Primary Capacity
Displayed Resolution
3000 x 1 lbs
3000
If primary capacity is 1500 x 0.5 kg, configure P7-P10 as follows:
Primary Capacity
Displayed Resolution
1500 x 0.5 kg
3000
Calibration Menu
Hold
Print
kg
Moves flashing digit
Calibration can be done with 10% to 100% of requested load and can be calibrated with 1 or 2 calibration points
On/Off
Zero
+
1.
Default
Definition
Displayed Resolution
10
Division Increment
0
Decimal Position
0
Calibration Weight
1
Units
Change flashing digits
Tare
(00) = 500
(01) = 600
(02) = 750
(03) = 800
(04) =1000
(05) =1200
(06) =1500
(07) = 2000
0 = 1 ; 1 = 2 ; 2 = 5
0 = 123456; 1 = 12345.6; 2 = 1234.56;
3 = 123.456; 4 = 12.3456; 5 = 1.23456
0 = KG ; 1 = LB
Units Selectable Capacity
1500 x 0.5 kg
Units Selectable Capacity
3000 x1 lbs
Tare
kg
Saves data and move down
to next Parameter setting
.
Detailed Setting
(08) = 2400
(15) = 7000
(09) = 2500
(16) = 7500
(10) = 3000
(17) = 8000
(11) = 3500
(18) = 10,000
(12) = 4000
(19) = 12,000
(13) = 5000
(20) = 15,000
(14) = 6000
(21-31) = N/A
P7
P8
P9
P10
10
0
0
1
P7
P8
P9
P10
10
2
1
0
On/Off
Zero
Exits setup mode