Other RS-232 Output Strings
P4-1 = Output Displayed data @ print key:
Format:
<LF>< reading, minus, decimal point, weight unit><CR><EXT>
P4-2 = Output Gross, Tare, Net at print key
Format:
<LF><Gross: reading, minus, decimal point, unit><CR><EXT>
<LF> <Tare: reading, decimal point, unit><CR><EXT>
<LF> <Net: reading, minus, decimal point, unit><CR><EXT>
RS232 Serial Interface Wiring
DE-9 Female Scale
Pin
Name
Direction
2.
TXD
Out
3.
RXD
In
5.
SG
Pins 1, 4, 6, 7, 8, 9 not used
Load cell cable interface wiring
1. Red Excitation+
1
2
1 RED
2. Black Excitation-
2 RED
3 RED
3. Green Signal-
3
4
4 RED
4. White Signal+
Scale Calibration
Calibration Configuration Settings
The scale is configured from the factory to match the specified settings for each unit, as defined by the product
specifications and sales brochure. Modification of the settings can be accomplished by altering user configuration
settings P7-P10. Caution: Calibration and/or configuration of calibration settings of your scale should be carried
out by a trained service technician, using certified weights, to ensure proper operation and accuracy. Calibration
is not covered under warranty.
Setup Controls
Hold
Print
kg
Moves flashing digit
DE-9 Male Host
Pin
Name
2.
RXD
3.
TXD
-
5.
Ground
1. Red Excitation +
2. Black Excitation -
3. Green Excitation -
4. White Signal +
Units
Changes flashing digits
Example:
xxxxx0.18lb
Example:
Gross: xxxxx0.36lb
Tare: xxxxxx0.18lb
Net: xxxxxxx0.18lb
Direction
In
Out
-
Tare
kg
Saves data and move down
to next Parameter setting
.
On/Off
Zero
Exits setup mode