SECONDARY AIR MANIFOLD REPLACEMENT

At the end of each burning season inspect the secondary air manifold for warping or deterioration. Replace if
necessary. At this time also check that the door gasket is not worn, frayed or loose. Replace with 1/2" (13mm)
EN
high density fibreglass rope if necessary. Check the airwash gasket located inside the appliance above the
door, replace if deteriorated. Contact your Napoleon dealer for specific type and size of the materials required.
NOTE: Do not operate appliance if the manifold, airwash shield or fibre baffle is deteriorated or missing.
To remove the secondary air manifold follow these instructions:
Remove the screws securing the side shields, slide
A.
them forward and remove from the appliance.
Remove the screws securing the rear shield, then
B.
remove the shield from the appliance.
Remove the rear bricks, then remove the baffle.
C.
Remove the 2 nuts and bolts securing the
D.
secondary air manifold in place, refer to the
illustration below.
Remove the secondary air manifold and gasket.
E.
To reinstall the secondary air manifold follow these
instructions:
Locate the slot at the front of the firebox chamber, as
A.
illustrated.
Insert the tab of the secondary air manifold into the
B.
above mentioned slot and pivot the secondary air
manifold into position.
A new gasket MUST be installed between the
C.
secondary air manifold and firebox.
Insert one of the bolts to hold the secondary air
D.
manifold in place.
E.
Working from the inside of the firebox, take the second
bolt and install it into position, loosely secure the washer and nut.
Remove the first bolt and reinstall as previously described in step E. Fully tighten both nuts and bolts.
F.
Reinstall the baffles and bricks.
G.
To reinstall the rear and side shields, refer to steps A and B of the removal instructions.
H.
NOTE: PUSH THE BAFFLE ALL THE WAY TO THE REAR OF THE FIREBOX, LEAVING A MINIMUM
OF 1" (25mm) GAP ALONG THE FRONT. THIS WILL ALLOW FLUE GASES TO PROPERLY ESCAPE THE
FIREBOX.
W415-1476 / D / 08.21.18
A
B
SIDE VIEW
SECONDARY AIR MANIFOLD
SLOT
AIRWASH
SHEILD