2.6
Concentric Flue Parts Identifi cation
The appending pages identify the parts that may be used in the Balanced Flue instalation
of this appliance.
Important note for Roof Terminations (C
When installing the appliance with a roof termination (classifi cation C31), it is im-
portant to fi t a 3 cm fl ue restriction strip (a) across the fl ue outlet inside the stove (Fig. 5,6).
Fig. 5
All manuals and user guides at all-guides.com
)
31
a
Fig. 6
2.7
Gas Connection
Please make absolutely sure that all pipings are installed and fi tted in compliance with the
applicable national regulations. A minimum pipe size of 15mm should be used for the gas
supply to within 1 metre of the appliance. 8mm pipe may only be used for the fi nal connec-
tion to the stove, or within 1 meter of the appliance. An 8 mm nut and olive is supplied with
the stove for the fi nal pipe joint.
A gas supply tap must be installed in the supply pipe work in a location that is easily accessi-
ble, such that the appliance may be isolated if necessary.
Do not make any connections to the appliance until all supply pipes have been purged to
expel any dust or debris. Failure to do this may result in a blocked injector or tap and will
invalidate the guarantee Although a gas soundness test is made on all appliances before they
leave the factory, the appliance should be tested for soundness before operating the stove.
This is to ensure that the burner has not been damaged in transit.
If thestove is connected with a rigid pipe, it is imperative to attach it
fi rmly to it's fl oor position.