On the main display screen (fig. 24), UFDS display indicates that
the (
) function is on, displaying the following information:
1 year of dive;
2 Dive date (month and day) - in brackets the number of
dive in a daily series of repeated dives;
NOTE: the first dive in a daily series is indicated in brackets
with 1 (meaning dive 1), the second one with 2 (dive 2), and
so on.
3 Maximum depth reached during the dive, expressed in m
or in ft;
4 Dive number: data on the latest dive are first
indicated.After the first 60 dives, the oldest ones are pro-
gressively erased;
5 Bar graph indicating residual nitrogen in the diver's tissues
at the end of the dive: if this value falls within the "green"
area, it means that a no decompression dive was per-
formed (within the safety curve). Conversely, if the graph
falls into the "red" band, it means that a decompression
dive was performed (outside the safety curve);
6 Altitude at which the dive was undertaken (see chapter
2.2.);
7 An icon with the word (
performed a Nitrox dive;
8 Graph indicating CNS toxicity level at the end of the dive
(see chapter.3.5.).
In all the three screens, icons will also be displayed of the
alarms, if any, that have been set off during your dive, such as:
) on it is displayed if you have
Nitrox
(
)(PO2 alarm); (
SLOW
PO2
In order to display the second Logbook screen, simply press
the button corresponding to the (
play. The (
) icon, which represents the first screen, is
replaced by the dive number followed by the "2/3" digit,
which means that you are looking at the second of the three
Logbook screens. The following data are displayed in this
second screen (fig. 25):
1 Time of dive start, namely the time when the dive com-
puter was brought below 5ft, thus turning on the "DIVE"
function;
2 Time of dive end, namely the time when the dive comput-
er was brought above 5ft, thus turning on the (
function;
3 Average dive depth (AVE) in m or in ft;
4 Total dive time in minutes and indicated with the"DIVE T."
icon.
To go back to the first screen (1/3), press the A button corre-
sponding to the (
) icon, whereas to move on to the third
Logbook screen, just press the B button correponding to the
(
) button of the UFDS display. The dive number followed by
(2/3) representing the second screen is then replaced by the
dive number followed by "3/3" representing the third of the
three Logbook screens. The following data are displayed in
this third screen (fig. 26):
1 type of air/Nitrox supply used during the dive: if it is a dive
with air, the word (
Nitrox, the Oxygen fraction employed will be shown;
148
) (maximum ascent rate alarm) etc.
) icon on the UFDS dis-
) will be displayed; if you are using
)
SURF.T

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Archimede 2