Additional information on
composition pipe "Copipe" :
x
Use only connections and fittings belonging to the system.
Install connections and fittings only on straight pipes, never
on bends.
Do not kink/break pipes, any accidentally kinked parts of the
pipe or damaged pipe ends must be removed.
Terpentin
Do not use paints, sprays, pens, cleaning agents, adhesive
tape etc. containing solvents on the pipes. When insulating
pipes, use only those materials which will cause no damage
to the pipe.
Protect pipes from deformation and mechanical damages.
max. 110 °C
Do not subject pipes to temperatures exceeding 110 °C.
Important :
Follow the instructions of Oventrop and manufacturers of
other components, as well as the guidelines, DVGW work
sheets and technical rules and regulations.
6
x
Protect from frost damage by draining pipes or adding a
suitbable antifreeze liquid to the heating system.
Protect pipes from direct sunlight (UV rays). Do not store in
the open without protection.
geprüft
Only use fluids which do not impair the conditions of the
pipe. Care must also be taken with additives for heating
systems and concrete mixes.