16.2.5 Protocols
Serial communication protocol
• PANASONIC: 9600baud, 19200baud
• PELCO D: 2400baud, 9600baud
• VIDEOTEC MACRO: 9600baud, 38400baud
16.2.6 I/O interface
Cable length: 200m (656ft) max
16.2.7 Camera
Power consumption (assembly, camera and lens)
• Without video encoder IP: 8W
• With video encoder IP: 6W
Minimum distance between camera and housing's
window: 4mm (0.2in)
Cameras dimensions/Lenses that can be installed
(WxHxL)
• Without video encoder: 70x65x140mm
(2,6x2,5x5,5in)
• With video encoder: 70mmx65mmx120mm
MNTCMVXTHD_1606_EN
16.2.8 Environment
Indoor/Outdoor
Installation temperature
• T5: from -60°C (-76°F) up to +65°C (149°F) or from
-50°C (-58°F) up to +65°C (149°F)
• T6: from -60°C (-76°F) up to +55°C (131°F) or from
-50°C (-58°F) up to +55°C (131°F)
Operating temperature: from -40°C (-40°F) up to
+65°C (149°F)
16.2.9 Certifications
ATEX (EN 60079-0: 2014, EN 60079-1: 2015, EN 60079-
31: 2014):
b II 2 G Ex d IIC T5 Gb
b II 2 D Ex tb IIIC T100°C Db IP66/IP68
-60°C ≤ Ta ≤ +65°C
b II 2 G Ex d IIC T5 Gb
b II 2 D Ex tb IIIC T100°C Db IP66/IP68
-50°C ≤ Ta ≤ +65°C
b II 2 G Ex d IIC T6 Gb
b II 2 D Ex tb IIIC T85°C Db IP66/IP68
-60°C ≤ Ta ≤ +55°C
b II 2 G Ex d IIC T6 Gb
b II 2 D Ex tb IIIC T85°C Db IP66/IP68
-50°C ≤ Ta ≤ +55°C
IECEx (IEC 60079-0: 2011 Ed.6, IEC 60079-1: 2014-06
Ed.7, IEC 60079-31: 2013 Ed.2):
Ex d IIC T5 Gb
Ex tb IIIC T100°C Db IP66/IP68
-60°C ≤ Ta ≤ +65°C
Ex d IIC T5 Gb
Ex tb IIIC T100°C Db IP66/IP68
-50°C ≤ Ta ≤ +65°C
Ex d IIC T6 Gb
Ex tb IIIC T85°C Db IP66/IP68
-60°C ≤ Ta ≤ +55°C
Ex d IIC T6 Gb
Ex tb IIIC T85°C Db IP66/IP68
-50°C ≤ Ta ≤ +55°C
IP66/IP68 (2 hours, 5m (16ft), EN/IEC60529)
37