Installation Guide - AMIX AFF 2 Serie Manuel Utilisateur

Afficheur de pression acoustique
Masquer les pouces Voir aussi pour AFF 2 Serie:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION GUIDE

It is good practice to plug in all the equipments before power on.
A/ Connections:
 Plug in CAP65 sensor to AFFseries-2.
Connect AFFseries-2 to the power supply
 For the first time, plug AFFseries-2 directly to your computer using the RJ45 port
(LAN on the rear panel). Attention, use a cross RJ45 wire.
 If you intend to use the dry loop outputs, use an other RJ45 wire.
Connect AFFseries-2 GPI/GPO 2 outputs to the remote equipment such as AFF05 display
etc... Otherwise make no connection.
PS 12V
AFFseries-2
RJ45
B/ Starting :
 Stand alone :
AFFseries-2 features a web server allowing to control from you favorite web browser. Open
your browser, enter AFFseries-2 IP address into the address window.
Default factory IP address is : 192.168.0.25.
http://
You can now access the web pages to set, analyse and read the AFFseries-2 internal
memory.
Attention, in case of difficulties, follows the procedure in "technical tools" annex
 Use on a net :
Connect AFFseries-2 to the net using the RJ45 connector.
Attention : To work properly the AFFseries-2 IP address should be unique on the network,
and in the available IP range. Should the PC or routeur net differ from AFFseries-2, first
modify PC or routeur to the same net as AFFseries-2, then set AFFseries-2 IP address as
described in "technical tools" annex.
AMIX - AFFseries-2
LAN
192.168.0.25
CAP65
GPO 1 OUT / GPO2 OUT
( to connect an AFF05 display and/or
AFF40 display for example )
PCS340
ATTENTION !! WARNING !!
36
ENGLISH

Publicité

Chapitres

Table des Matières
loading

Table des Matières