Technical specifications
Parameter
General specifications
Weight
Emissions
Output relay
Breaking capacity output relay
Relay fuse
Operating pressure in interstitial space Approx. -400 mbar
Switching point Alarm On
Switching point Alarm Off
Switching point Pump On
Switching point Pump Off
Connecting hose
Operating temperature range
Ambient
Outdoor installation with protective
housing and heating
Storage
Supply voltage
Nominal voltage
Nominal power
Electrical safety
Protection class
Degree of protection
Mode of operation and additional mode
of operation
Electromagnetic compatibility (EMC)
Emitted interference
Product description
Value
1.1 kg
The A-evaluated sound level of
the audible alarm is at least 70
dB(A) at a distance of one metre.
1 changeover contact
Max. 250 V, 2 A, resistive load
T 2 A
-340 ± 10 mbar
-380 ± 10 mbar
-380 ± 10 mbar
-420 ± 10 mbar
PVC hose 6 x 2 mm
-5/+60 °C
-25/+60 °C
-25/+60 °C
AC 100 - 240 V ± 10 %
< 10 VA
II (EN 60730-1)
IP 30 (EN 60529)
Type 1.B
CISPR 22
Eurovac HV
EN
15