Télécharger Imprimer la page

Shure FP410 Mode D'emploi page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

WARNING
Voltages in this equipment are hazardous to life. No us-
er--serviceable parts inside. Refer all servicing to quali-
fied service personnel.
In addition to the user--modifiable functions described
above, the FP410 is designed so that many of its functions can
be modified by a qualified technician. Instructions on imple-
menting these modifications are provided in the FP410 Ser-
vice Manual which is obtainable from Shure. These modifica-
tions are:
1. Change Monitor In sensitivity.
2. Change Tape Out level.
3. Change Off--Attenuation value.
4. Change low--cut filter frequency.
5. Change Peak meter attack and decay time constants.
6. Change 0 VU Meter calibration to level other than +4 or +8
dBm.
7. Change Limiter threshold beyond the positions permitted by
Switches 2 and 3 (see Figure 2).
8. Change to permanently lock one or more microphones on.
9. Change to permanently prevent one or more microphone
channels from activating.
10. Change the preset Hold Time values.
11. Change the Monitor In jack to an Aux In jack function for
cascading mixers or creating a "mix--minus".
12. Change to provide reduced--level program feed in head-
phones when Pull For Monitor switch is activated.
13. The FP410 can be changed to operate from 230 Vac, 50/60
Hz power. Similarly, the FP410E can be changed to operate
from 100 to 120 Vac, 50/60 Hz mains voltage.
WARNING
The safety certifications of the FP410 and FP410E do not
apply when the operating voltage is changed from the
factory setting.
ADDITIONAL INFORMATION
Limiter
The front--panel Limiter switch turns on a fast--acting, peak--
responding limiter circuit that cuts overload distortion during
loud program intervals without affecting normal program lev-
els. When the switch is In (operating), the FP410 output is lim-
ited to approximately +16 dBm. Increasing the individual or
Master gain controls will increase the average output and the
amount of limiting. The limiter threshold can be changed from
its factory setting as described in the Modifiable Functions
section. The front--panel red LED adjacent to the Limiter
switch indicates limiter action.
Linked Mixers
The FP410 provides four microphone inputs. If additional
mic inputs are needed, more FP410s (over 25, if necessary)
can be "linked" using link cables of the type supplied. A setup
like this can provide over 100 mic inputs. As long as the link
jacks of all mixers are connected (out--to--in, sequentially,
leaving one Link In and one Link Out jack unconnected), the
automatic mixing functions will be shared by all units.
When FP410 mixers are linked, Shure Intellimix control
functions are also linked so that a single multi--microphone
system is created. All input signals (except the Monitor In sig-
nal) appear at all linked mixer outputs. There is no master/
slave relationship.
The output--related controls and functions of each linked
mixer are post--link and do not affect the signals appearing at
other linked mixer outputs. Each mixer's output controls may
be set differently to obtain different results. These controls are:
Master level control, 1 kHz Tone Oscillator, Peak/VU Meter
switch, Limiter In and Limiter Threshold switches, Phone level
and Monitor control, and Off--Attenuation switch. NOTE: The
actual off--attenuation in the 13 dB switch position increases,
as more mixers are linked. This reduces excessive noise and
reverberation contributed by the increased number of typically
"off" microphones.
The input--channel--related controls and functions of each
linked mixer are pre--link and do not affect the input channels of
other linked mixers. The effect of these input controls is re-
flected in the mixed output signals of all the linked mixer out-
puts. These controls are: Input channel levels controls and
Low--Cut switches, Manual/Auto switch, Phantom On/Off
switch, Phantom Voltage Selector switch, Hold Time switch,
and Last Mic Lock--On switch.
Link Cables
Additional link cables can either be purchased (Shure Part
No. 95A1143; 305 mm—12 in.) or constructed using desired
lengths of high--quality, 7--conductor, shielded cable (pin 1:
shield) with 8--pin mini DIN connectors on each end. The maxi-
mum length of a link cable will depend on the grounding con-
siderations of this unbalanced line.
FP410 and Mixing Consoles
The FP410 can be used in conjunction with large mixing
consoles to provide automatic mixing for talk shows, panel dis-
cussions, and nightly news shows. Large consoles have chan-
nel insert jacks so that external signal processing devices can
be patched into individual channel signal paths. These jacks
are normally line level.
The FP410 can be fed from these insert jacks and the
FP410 output then fed to a submaster fader on the console.
This arrangement allows the operator complete control of
each channel via the console's input control strip, while the the
FP410 keeps the number of open microphones to a minimum,
relieving the operator of having to open and close mic chan-
nels.
SUPPLIED ACCESSORIES AND REPLACEMENT
PARTS
Battery Tray Assembly
Bumper (Foot) Kit (4 in kit))
Control PC Board Assembly
Knob, Master & Phones
Knob, Channel Gain
. . . . . . . . . . . . . . . . . . . . . . . .
Line (Power) Cord (FP410)
Line (Power) Cord (FP410E)
Link Cable
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Left Rack--Mount Bracket
Right Rack--Mount Bracket
5
. . . . . . . . . . . . . . . . . . . . .
90GJ2600
. . . . . . . . . . . . . . . . . .
90S8100
. . . . . . . . . . . . . . . .
90B8368A
. . . . . . . . . . . . . . . . . . . . .
95A8238
95B8238
. . . . . . . . . . . . . . . . . .
95A8231
. . . . . . . . . . . . . . . . .
95A8247
95A1143
. . . . . . . . . . . . . . . . . . . .
53A8252
. . . . . . . . . . . . . . . . . .
53A8253

Publicité

loading