Technical data
– Measuring range overshoot/undershoot
10.5.2 Operating elements
Jog/shuttle dial
10.5.3 Remote operation
Configuration
The device can be configured with the PC software ReadWin
Interface
CDI interface at device; connection to PC via USB box (see 'Accessories')
RS232 interface at device; connection with serial interface cable (see 'Accessories')
10.6 Certificates and approvals
10.6.1 CE mark
The device meets the legal requirements of the EU directives. Endress+Hauser confirms that the
device has been tested successfully by affixing the CE mark.
10.6.2 Ex approval
Information about currently available Ex versions (ATEX, FM, CSA, etc.) can be supplied by your
E+H Sales Center on request. All explosion protection data are given in a separate
documentation which is available upon request.
10.6.3 Other standards and guidelines
• IEC 60529:
Degrees of protection by housing (IP code)
• IEC 61010-1:
Protection measures for electrical equipment for measurement, control, regulation and
laboratory procedures
• CSA 1010.1
Safety requirements for electrical equipment for measurement, control, and laboratory use -
General requirements
• FM 3610
Intrinsically safe apparatus and associated apparatus for use in class 1, 2 and 3, division 1
hazardous (classified) locations
• CSA C22.2.157
Intrinsically safe & non-incendive equipment for use in hazardous locations
• CSA E79-11
Electrical apparatus for explosive gas atmospheres - intrinsic safety "i"
• EN 50020
Electrical apparatus for hazardous areas - intrinsic safety "I"
152
®
2000.
RIA452
Endress+Hauser