Rev.1 29/07/2021
Pag.22

User training

Once installation is complete, the user must always be fully trained in the functions and characteristics of the stove by the technician
authorized by Ravelli to ensure optimal and safe use.
The training should cover the following topics:
Description of the stove, its operation and basic settings
How to turn the stove on and off safely
Fuel storage and refilling
What to do in the event of an alarm, in particular that of "no ignition"
How to clean the stove correctly and the importance of performing it on a regular basis
It is advisable to schedule the first annual maintenance

Safety devices

The stove has been designed and equipped with safety systems to minimize user risks.
It is equipped with the safety devices listed in the following table, which also intervene in case of failure of the electronic board.
Element
Pellet tank thermostat
Pressure switch
Electrical safety
It should be noted that the stove's operating program has been designed to stop stove operation in the event of malfunctions:
Anomalies
Flue gas temperature
Smoke fan break
Gear motor failure
Temporary power failure
No ignition
It is forbidden to tamper with the safety devices. Restarting the product is only possible after eliminating the cause that
caused the intervention of the safety system. To understand which anomaly occurs, consult this manual which explains,
depending on the alarm message that the device displays, how to intervene on it.
If the problem persists, contact the Support Service.
Use and maintenance manual R 1000 Pro
Description
If the temperature exceeds the set safety value, it immediately stops the pellet loading
motor and the stove is automatically switched off; to restart it, it is necessary to wait until
it has cooled down and manually reset the thermostat, using the appropriate button.
If the pressure in the smoke outlet duct is too high (a sign that the smoke evacuation sys-
tem is obstructed) it immediately stops the pellet loading motor and the stove switches off
automatically.
In case of failure of the electrical components or wiring, the fuse and grounding keep the
appliance safe. It is necessary that the electrical system of the house is up to standard,
equipped with a grounding circuit and all the safety systems required by the standards.
Description
If the temperature probe at the smoke outlet detects temperatures that are too high, the
stove is switched off and the relative alarm is displayed.
If the fan stops, the electronic board blocks the supply of pellets and the alarm is dis-
played.
If the gear motor stops, the appliance switches off safely.
If a power failure occurs during operation, when the power returns the temperature in the
combustion chamber is checked and, if necessary, the stove goes into cooling mode.
If no flame develops during the ignition phase, the stove goes into alarm.