CONNECT THE WATER LINE
4
the top right condenser mounting clip for better
access to the water tube inlet.
Make sure there is enough plastic water line to
extend from the water valve to well into the
kit with pliers and slide the clamp over the water
tube inlet.
plastic water line into the inlet as far as it will go
Then slide the clamp downward to capture the
plastic water line in place.
Make sure the fill tube is aimed down.
secure the condenser to the refrigerator by
replacing the mounting clip and screw.
Do not overtighten the screw.
Water tube
inlet
ROUTE AND ATTACH THE
5
PLASTIC WATER LINE
Fasten the plastic water line to the back of the
cabinet with adhesive-backed fasteners
spacing the fasteners as shown to take up slack
screw from the top right condenser mounting
clip for better access to the water tube inlet.)
Adhesive-backed fasteners
for plastic water line
49-60704-2
Installation Instructions
3
WATER VALVE INSTALLED
6
connection to the home water supply. After water
line installation is completed, set the icemaker
power switch to ON.
The icemaking cycle will not begin until the
icemaker and freezer compartment reach
operating temperature, then icemaking will
begin automatically.
REINSTALL THE COVER
7
Reinstall the compressor compartment access
removed previously to reattach the cover to
the back of the refrigerator case. This must be
reinstalled for your refrigerator to function properly.