Gas supply
Gas Connection: ¾'' (19 mm) N.P.T. with a min. ¾''
(19 mm) diameter flex line.
The appliance is connected only to the type of gas
for which it is certified for use.
Manual gas shut off valve installed in an accessible
location (without requiring removal of range).
Owner is aware of location of the gas shut-off valve.
Unit tested and free of gas leaks.
If used on propane gas, verify that the propane gas
supply is equipped with its own high pressure
regulator in addition to the pressure regulator
supplied with the appliance.
Gas supply pressure does not exceed 14'' W.C.
(34.9 mbar).
Refer to the Use and Care Guide for information
about cleaning and protect exterior surfaces.
Electrical
Receptacle with correct over-current protection is
provided for service cord connection.
Proper ground connection.
Owner is aware of location of the main circuit
breaker.
Operation
Bezels centered on burner knobs, and knobs turn
freely.
Each burner lights satisfactorily, both individually
and with other burners operating.
Oven door hinges seated and hinge locks in proper
position. Oven handle and door is level and
centered. Door opens and closes properly.
Burner grates correctly positioned, level, and do not
rock.
INSTALLER: Write the model number and serial
number in the Use and Care Guide. Leave the Use
and Care Guide and Installation Instructions with the
owner of the appliance.
Troubleshooting
See the Use and Care Guide for troubleshooting
information.
22