Before you plug in an electrical cord, be sure all
controls are in the OFF position.
A neutral supply wire must be provided from the
power source (breaker) because critical range
components, including the surface burner spark
reignition modules, require it to operate safely and
properly.
All 120 volt models must be plugged into a mating 3-
prong, grounding-type receptacle. The receptacle
must be connected to a properly dedicated grounded
and polarized electrical power supply rated at
120VAC, single phase, 60Hz.
Observe all governing codes and ordinances when
grounding. In the absence of these codes or
ordinances observe National Electrical Code ANSI/
NFPA 70 current issue, or the relevant Canadian
Electrical Code, CSA C22.1 latest edition.
Power cord connection
9 WARNING
To avoid risk of fire or electrical shock:
Do not allow the power cord to go beneath the range
while moving the appliance to its permanent position.
The power cord can become dislodged underneath
the product, exposing it high temperatures which can
cause the power cord to melt.
Follow the instructions carefully.
Restraining the power cord
1. Wrap the power cord two loops, approximately 7''
(178 mm) diameter each, behind the appliance.
7"
(178)
2. On the bottom left, route the power
cord through the self-locking clip.
3. Before placing the appliance in its final location,
Setting the power cord guard — 36'' and 48'' Pro
Grand models
1. At the base of the range, loosen the two (2) T-20 star-
2. Slide the power cord guard down, as shown below,
Electrical requirements and connection
for DUAL FUEL models
9 WARNING
An improper 240/208 VAC power supply will cause
malfunction, damage to this appliance, and possibly
create a condition of shock hazard.
2"
(51)
9 WARNING
This product must be properly grounded.
ensure there is enough slack to allow the cord to reach
the power outlet, approximately 28'' – 30''
(711 – 762 mm).
NOTE: Plug styles may vary.
head screws securing the power cord guard.
and re-secure the screws. This will further prevent the
power cord from entering the area under the base of
the range.
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being
turned ON accidentally.
Prior to servicing appliance, always disconnect
appliance electrical supply cord, if so equipped, from
wall receptacle. If appliance is hard-wired to power
supply, disconnect power to unit by turning off the
proper circuit breaker. Lock service panel to prevent
power from being turned ON accidentally.
A neutral supply wire must be provided from the
power source (breaker) because critical range
components, including the surface burner spark re-
ignition module, require it to operate safely and
properly.
Mount the receptacle securely to a wall stud, then seal
around the receptacle's housing.