8. Secure the bare copper ground lead to the range
chassis using the green ground screw and serrated
washer. Be sure that neutral and ground terminals do
not touch.
a
a – Red/L1
c – White/neutral
9. Tighten all connections securely and
10. Reinstall the terminal block cover.
3-wire lead connection
Where local codes and ordinances permit grounding
through neutral, and conversion of supply to 4-wire is
impractical, the unit may be connected to the power
supply with a Listed (UL, CSA, ...) 3-POLE, 3-
CONDUCTOR cord kit rated 125/250 VOLTS, 50
AMPERES DEDICATED CIRCUIT, and marked for use with
ranges. It is the responsibility of the installer to provide
the proper wiring components (cord, wires, etc.) and
complete the electrical connection as dictated by local
codes and ordinances, and/or the National Electrical
Code.
The cord kit must be attached to the range back panel
with a strain relief which will fit a 1" (25.4 mm) diameter
hole. If not already equipped, the cord must also have
1/4'' (6 mm) faston closed-loop lugs attached to the free
ends of the individual conductors, preferably soldered in
place.
To wire a 3-wire connection
1. Locate the small bag with white jumper wire located in
the literature packet.
2. Locate the terminal block on the rear of the unit and
remove cover.
3. Remove upper nuts only from the terminal block
studs. DO NOT remove nuts which secure range
internal wiring leads.
4. If applicable, remove the 4-wire power cord from the
appliance.
d
c
b
b – Green/ground
d – Black/L2
5. Mount strain relief (not provided with range) into the
1'' (25.4 mm) diameter hole in the back panel located
below the terminal block. Route wires up through
strain relief.
6. Secure the neutral, grounded wire of the supply
circuit, to the center stud (silver colored) of the
terminal block.
7. Secure the L1 (red) and L2 (black) power leads to the
outside corresponding terminal block studs (brass
colored).
8. Remove the green ground screw and serrated washer
located beneath the terminal block. Screw one end of
the included white jumper wire to the chassis beneath
the terminal block with the green ground screw.
Secure the other end of the wire to the center stud of
the terminal block with nut.
a
a – Red/L1
b – Ground link wire provided in
small bag.
c – White/neutral
d – Black/L2
9. Tighten all connections and nuts securely.
10. Reinstall the terminal block cover.
d
c
b
16