The range is supplied with its own pressure
regulator that has been permanently mounted
within the range body.
2. Use a ¾'' (19 mm) flex line to connect between the gas
supply and the appliance gas inlet. The gas supply line
connection is located at the lower right portion of all
range models (see Figure 9). The appliance gas inlet
connection is ½'' (12.7 mm) NPT.
Use caution to avoid crimping the ¾'' (19 mm) flex
line when making bends. Suggested length of flex
line is 48" (1219 mm); however, please check local
codes for your area's requirements before
installation.
3. Use pipe sealing compound or Teflon
pipe threads. DO NOT apply sealing compound or tape
to flare fittings. Take care not to apply excessive
pressure when tightening the fittings.
¾" (19 mm) external threads
½" (12.7 mm) internal threads
Manual gas shut-off valve
Manual gas shut-off valve
4. Leak testing of the appliance shall be in accordance
with the following instructions.
Turn on gas and check supply line connections for
leaks using a soap and water solution.
Installation Instructions
®
tape on the
{
Adapter
Adapter
Adapter
or
¾" (19 mm)
¾" (19 mm)
¾" (19 mm)
Flex line
Flex line
Flex line
or
Adapter
Figure 9: Gas Supply Connection
Bubbles forming indicate a gas leak. Repair all
leaks immediately after finding them.
WARNING
Do not use a flame of any kind to check for gas
leaks.
CAUTION
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off
valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2
psig (3.5kPa.).
STEP 6: Electrical
Requirements, Connection &
Grounding
Model
Voltage
30" with 4
120 VAC 10 Amps
burners
36" with 6
120 VAC 10 Amps
burners
36'' with griddle
120 VAC 20 Amps
or grill
48'' with griddle
120 VAC 20 Amps
or grill
Table 2: Electrical Supply Circuit Requirements
WARNING
An improper 120 VAC power supply will cause
malfunction, damage to this appliance, and possibly
create a condition of shock hazard.
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being turned
ON accidentally.
For these gas range models, a neutral supply wire must be
provided from the power source (breaker) because critical
range components, including the surface burner spark
reignition modules, require 120 VAC to operate safely and
properly.
Circuit
Frequency Phase
Rating
60 Hz.
Single
60 Hz.
Single
60 Hz.
Single
60 Hz.
Single
English 15

Publicité

Table des Matières
loading