Start-Up; Filling Self-Priming Pump With Water; Checking How Easily The Pump Rotates; Switching On The Pump - Speck pumpen BADU 90 Fiche Technique

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 67
6

Start-up

The pump can be damaged if it runs dry.
6.1

Filling self-priming pump with water

1. Remove lid, see Chapter 8.1, page 49.
High concentrations of water treatment chemicals can damage the
pump!
2. Fill pump with clean water up to the inlet connection.
3. Replace the lid and tighten it by hand.
6.2

Checking how easily the pump rotates

After longer idle periods, the pump must be check for how easily it
rotates while it is switched off.
– or –
6.3

Switching on the pump

Prerequisites:
1. Open the valve on the intake side completely.
2. Only open the valve on the delivery side halfway.
06/2014
VG 766.2000.055
Ensure that the pump is full of water. This also applies to checking
the rotation direction.
Do not place water treatment products, particularly in tablet form, for
example chlorine tablets, into the strainer basket.
To make it easier to open the lid the next time, tighten the lid by
hand only.
Place screwdriver in the groove on the end of the motor shaft on the
fan side and turn it clockwise.
If there is not a groove on the end of the motor shaft: Remove fan
cover and turn the fan wheel in the motor rotation direction
manually.
Strainer basket is installed, where applicable.
Lid is fitted securely.
6 Start-up
EN 45

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Badu 90-ak

Table des Matières