During normal operation, the 'mode' LEDs can indicate the following:
LED status
100...1400VA
100...1400VA
Upper LED lights steadily.
100...1400VA
100...1400VA
Lower LED lights steadily.
100...1400VA
100...1400VA
Upper LED blinks.
100...1400VA
100...1400VA
Lower LED blinks.
5. TROUBLESHOOTING
- Possible causes of dimmer malfunction:
- mains voltage not connected
- load not connected
- control not connected or connected incorrectly
- fault on the DALI bus
- defective lamp
- thermal protection activated
- combination of above causes
EN
meaning
100...1400W
Current mode: reverse phase control mode, automatic
100...1400W
Current mode: phase control mode, automatic
100...1400W
Current mode: reverse phase control mode: manually
Load = incandescent lamp, low tension halogen lamp with
electronic transformer
100...1400W
Current mode: phase control mode, manually
Load = incandescent lamp, halogen 230V~, low
tension halogen with ferromagnetic transformer.
ε
R,L,C