CAUTION:
Earthed water pipes may give the appearance of a
connected protective earth.
• To guarantee compliance to relevant safety
regulations, an all-pole separator must be fitted
during installation, according to chapter 3. The
contact opening must be at least 3 mm.
• This appliance can be installed with three (3)
different configurations corresponding to three(3)
rated power values ( chapter 2).
• Ensure that the inlet water pressure, maximum and
minimum, is according with the value specified by
the manufacturer ( chapter 3).
• The water inlet of this appliance shall not be
connected to inlet water obtained from any water
heating system.
• The continuous-flow heater is only suitable for
closed (pressurised) operation.
• The tap and outlet fittings must be approved for
operation with closed (pressurised) continuous-
flow heater systems.
• Only connect the continuous-flow heater to a cold
water line. A non-return valve must NOT be
connected to the cold water.
• Do not use plastic pipes. Steel or copper pipes are
suitable for the cold-water supply. Insulated copper
pipes are particularly suitable for the hot-water
pipes.
• The appliance is suitable for supplying water for
multiple points of use, including showers.
• The appliance should be installed close to the
tap that is used the most frequently.
• Disconnect the electrical connection cable from
the supply and shut off the water supply before
connecting the appliance!
• Connect the water supply and then connect the
electrical supply.
• Only make the openings which are required for
installation on the rear of the appliance. If the
appliance is reinstalled, the unused openings must
be provided with watertight sealing.
• Do not touch electrically live parts after installation.
• The appliance should be disconnected from the
electrical mains supply when working on the water
supply. After service work is complete, proceed as
during the first-time appliance start-up.
• No changes may be made to the appliance.
• The appliance may only be used for heating drinking
water for household use.
TR1000 12 B – 6 720 876 017 (2020/10)
• The mixer and the warm water pipe may be hot.
• Do not use aggressive or abrasive cleaning
detergents!
• Do not use a steam cleaner.
• The appliance is only to be descaled by a suitably
qualified specialist.
Safety of electrical devices for domestic use and
similar purposes
The following requirements apply in accordance with
EN 60335-2-35 in order to prevent hazards from
occurring when using electrical appliances:
"This appliance can be used by children of 3 years and
older, as well as by people with reduced physical,
sensory or mental capabilities or lacking in experience
and knowledge, if they are supervised and have been
given instruction in the safe use of the appliance and
understand the resulting dangers. Children shall not
play with the appliance. Cleaning and user
maintenance must not be performed by children
without supervision."
"If the power cable is damaged, it must be replaced by
the manufacturer, its customer service department or
a similarly qualified person, so that risks are avoided."
Please read this installation and operating
instruction manual carefully, then act accordingly!
Store for future reference.
Congratulations on purchasing this BOSCH appliance.
You have acquired a top-quality product, which will
give you a lot of enjoyment.
2
Installation instructions
Install the continuous-flow heater as described in the illustrated
section. Observe the instructions in the text.
The illustrations can be found in the centre of the instruction manual.
2.1
Installation
I. List of items supplied
1. Continuous-flow heater
2. Installation template
3. Connection piece for hot water
4. Washer, red Ø 15 mm
5. Connection piece for cold water
6. Washer, Ø 24 mm
7. Mounting bolt
8. Wall plug
9. Securing nut
10.Threaded bushing
11.Cable grommet
II. Wall mounting
There are two ways in which the continuous-flow heater can be mounted
on the wall:
• Using the mounting bolt. Unevenness in the wall up to a depth
of 25 mm can be compensated for.
Installation instructions
9