1.3 ACCESSORIES' CONNECTION
EXTERNAL ANTENNA with shielded cable
It improves the radio receiving of the control unit.
It is better to install at a 2 meters height and far away from other disturbing electromagnetic sources.
The CABLE SHIELDING must be connected to the terminal 22.
The WARM POLE must be connected to the terminal 23.
FLASHING LIGHT (230Vac 40W intermittent)
It operates during the opening and closure operations.
It must be connected to the terminals 18 and 19 (flash)
ATTENTION! The output of the terminals 18 and 19 is 230 Vac!
COURTESY LIGHT
LThe output of the courtesy light is a no-tension contact with 5A max., which operates automatically during the door opening.
Two working modes are available:
- Ignition at every opening with automatic switch-off after 3 minutes if the board's dip 5 is
in OFF position.
- As an ignition control for lighting systems at every opening when the board's dip 5 is in ON
position.
The contact's output is at the terminals 13 and 14 (AUX)
ATTENTION! Max loading capacity is 5A at 230 Vac
2. 230V~ CONNECTION BOARD
2.1 CONNECTION OF THE MOTOR AND OF THE POWER SUPPLY
ATTENZIONE! The system must be provided along with a switch featuring a of 3mm (at least) contacts' opening, able to
assure the omnipolar disconnection of the system. The wiring operations must be performed only after having
disconnected the main power supply! SWITCH OFF THE MAIN POWE SUPPLY before performing any other operation!
CONNECTION
SINGLE PHASE MOTOR
230 VAC MAX 500W
MAIN POWER SUPPLY
TO THE POWER NET
230Vac 50-60Hz
CONNECTION TERMINALS
Connect the motor lines to the terminals 15 and 16.
Connect the common wire of the motor to the terminal 17.
Connect the lines of the power supply to the terminals
20 (L) and 21 (N)
Control unit with integrated receiver
QCzero QCzeroP
22 23
18 19
MAX 40 W
FLASH
230V~/50 Hz
13
14
max 5A
IMPORTANT
15 16 17
20 21
M
L
N
230Vac 50-60Hz
EN
23
20
21
C