QCzero QCzeroP
20
EN
WIRING DIAGRAM CONNECTION*
1
2
3
4
*
The control unit is provided along with three bridges to be used in case no safety beams and edges (Note: only when
required by law) or stop buttons are installed in the following connectors:
- Stop connectors 5-6;
- Safety edge connectors 7-8 (with dip 4 in OFF position);
- Safety beam connectors 8-9.
CONNEC-
TION
DESCRIPTION
TERMINALS
1
UP - N.O.
2
COM
3
DOWN - N.O.
4
START/STOP - N.O.
5
COM
6
STOP - N.C.
7
EDGE
8
COM
9
PHOTO - N.C.
Control unit with integrated receiver
5
6
7
8
9 10
11
12 13 14 15
24 Vac
AUX
CONNEC-
TION
DESCRIPTION
TERMINALS
10-11
SAFETY BEAMS' POWER SUPPLY
12
TEST - SAFETY BEAM'S TEST
13-14
AUX - COURTESY LIGHT - N. O.
15
MOTOR
16
MOTOR
17
MOTOR COMMON
18-19
FLASH - FLASHING LIGHT INTERMIT.
20
L - PHASE
21
N - NEUTRAL
230 V~
16 17 18 19 20 21
C
M
50-60Hz
24V~ / 140 mA
MAX 250V~ / 5A
230V~ / max 500W
230V~ / max 40W
230V~ / 50/60 Hz
POWER SUPPLY
L
N
230Vac