CONTROL PANEL
Installation (SEE PAG. 20)
-
A differential or magnetothermic 10 A switch shall be mounted on the top of the
equipment, in order to assure an omnipolar sectioning with a minimum contact opening
equal to 3 mm.
-
The power supply cables (min 1.5 sq.mm) shall be differentiated in comparison with
the signal cables (min 0.5 sq.mm).
-
Possible contacts connected with the N.C. input shall be arranged in series one to
the other.
-
Possible contacts connected with the N.O. entrance shall be arranged in parallel.
CONNECTIONS
1-2 : POWER SUPPLY: 230 Vac 50 Hz.
1= PHASE , 2 = NEUTRAL, FS1 = EARTH .( F1) 160 mA protection fuse
3-4 : FLASHING LIGHT connection 230 Vac - 100 W max. (see Dip 4 )
( F4) 500 mA protection fuse
5-6-7 : MOTOR connection.
5=common , 6=opening ,7=closing . External capacitor connected with FS3-FS4 connec-
tors .
( F3) 5 A protection fuse
8-9 : Output for 230 Vac 200 W max courtesy-lamp.
Connection of dry contact ( N.O.) which is closed for whole gate stroke and for additional
2 minutes after stopping.
10 -11: connection ( SELV ) 24 Vac - 5W max for ACCESSORIES POWER SUPPLY.
( F2 ) 500 mA protection fuse
12 - 14 : N.O. input for PEDESTRIAN START command .
It only operates when the closing limit switch is activated : it controls a 10 secs opening,
followed by a fixed 10 secs pause time and an automatic closing.
13 - 14 : N.O. input for START command (see DIP 3 ).
16-14 : N.C. input for detecting devices ( PHOTOELECTRIC CELLS ). See DIP 5 .
15 -14 : N.C. input for STOP command
It causes a stopping during opening and closing and it also stops the pause time inhibiting
a new automatic closing.
17 - 18 : 24 Vac output for warning light ( max 3 W ) .
It indicates the position as well as the movement positions of the gate ( Warning light off =
gate closed ; Warning light on = gate open; slow flashing during opening ; quick flashing
during closing ).
19-20-21 : MOTOR REVOLUTIONS SENSOR.
19 = blue ; 20 = brown ; 21 = black (see DIP 6 ) .
22-23 : EXTERNAL AERIAL ( 23 = shielding )
WARNING : should you utilize a plug in receiver equipped with its own termi-
nals to be connected with the aerial, do not consider 22-23.
( Dip- Switch Sw1 ) FUNCTIONS PROGRAMMING
Warning : to store a new configuration, the voltage must be disconnected for few
seconds.
DIP 1
DEAD MAN LOGIC
OFF = Disabled ( = pulse functioning )
ON = Enabled. It works only by continuous activation of START
command (13-14 terminals). Once the contact is N.O. again, the
motion stops.
Dip 2
AUTOMATIC CLOSING
OFF = Disabled
ON = Enabled
Dip 3
Response to repeated START commands (13-14 terminals )
OFF = " Condominium Programme ".
OPENING –CLOSING - only when opening limit switch is activated-
during Closing , STOPPING and NEW OPENING.
ON = " Step-by-Step Programme " . OPENING - STOPPING -
CLOSING - STOPPING etc...
Dip 4
2 seconds pre - flashing
OFF = Disabled
ON = Enabled
Dip 5
Input enabling for detecting devices (16-14 terminals )
OFF = It operates during closing , with stopping and new opening
ON = It operates during opening and closing, with stopping and
a new opening when the photoelectric cells are released.
Dip 6
INDUCTIVE SENSOR Enabling
OFF = DISABLED
ON = Motor revolutions counting enabled both during opening
and closing. The device operates during opening and closing. The device operates in
case of impacts against obstacles and in this case, a stopping as well as a motion
reversal for 2 seconds occur. ( WARNING: position on ON in versions equipped with
inductive sensor, only ).
12
TRIMMER SETTING
RV1 WORK : predetermine a WORKING TIME exceeding 5 ÷ 8 seconds in comparison
with a real time for a complete procedure. Setting enabled with Dip 1 = OFF, only .
RV2 PAUSE : only by Dip 2 = ON, it is possible to set the PAUSE TIME; as the Pause
Time ha s expired, the gate automatically closes. During the pedestrian cycle , the
automatic closing always occurs after a 10 secs pause ( fixed ).
STARTING AND TESTING
With power supply disconnected:
-
Set Dip-switches according to the functions you needed;
-
Assure that connections have been carried out correctly, because a possible error
could damage the equipment in irreparable way.
With power supply connected:
-
Carefully carry out settings on the trimmers
-
Assure that the red LED relating to N.C. inputs are ON, according to the operator
conditions;
-
Assure that the yellow LED referred to START and PEDESTRIAN START inputs are
only enabled in case of operation;
-
Assure that possible safety devices connected with the PHOTO ( 14 -16 ) or STOP
( 14-15 ) inputs are correctly functioning.
-
Assure there is a correct direction ( the first START command after enabling supply,
if the gate is not at the opening limit switch yet, an opening occurs ). If it is not the case, you
shall invert the connections of 6-7 terminals one to the other. When the gate is open wide,
the opening limit switch LED shall be OFF and the closing limit switch LED shall be ON;
when the gate is closed, the closing limit switch LED shall be OFF and the opening limit
switch LED shall be ON.
VERSION WITH INTEGRATED RECEIVER
The equipment version with integrated 433.92 Mhz receiver can function with dip-
switch as well as Roller ( Rolling Code ) transmitters, it can store max 200 different
codes.
Transmitters learning:
Supplying the equipment for the first time, assure that DL9 is on ( receiver ready for
storage ).
You only need to press the button related to the first transmitter channel in order to store
the code in the receiver ( that button operates as START command ). Automatically, the
second transmitter channel is also stored and the relevant button operates as PEDES-
TRIAN START command (cut JP4 jumper to exclude such function ) .
The DL9 LED is ON for 6 seconds more and in the same way, it is possible to learn
further transmitters belonging to the same category.
The storage phase ends automatically when the DL9 LED turns OFF.
In order to learn additional transmitters, you shall press the P1 ( LEARN ) button, assure
that DL9 LED turns ON, then press the new transmitter button.
Warning : after learning the first transmitter, the receiver only accepts other transmitters
belonging to the same category (DIP or ROLLER).
Total cancellation of stored codes : press the P1 button (DL9 LED is ON ) and keep
it pressed until DL9 LED is OFF.
Releasing the P1 button, the DL9 LED flashes once, then, it turns ON again to indicate
that the receiver is ready to learn new remote controls.
ROLLER category remote controls learning without accessing the control
equipment:
when at least one transmitter has already been stored by the above described proce-
dure , it is possible to enable a self-learning of new transmitters belonging to the same
category, without accessing the control equipment.
In fact, you only need to press simultaneously 1 and 2 buttons of the already stored
transmitter ( near to the location of the operator) for a few seconds, and then press the
new transmitters button, in order to learn it.
INDUCTIVE SENSOR
The sensor cable n° 2 shall be connected following the combination terminal/
colour: 19 = blue , 20 = brown, 21 = black, then set DIP 6
TECHNICAL FEATURES
Operating temperature : - 20 ÷ + 55
Power supply voltage : 230 Vac ± 5 %
Frequency : 50 - 60 Hz
Accessories power supply connection: 24 Vac max 200 mA
Flashing light: 230 Vac max. 100 W
Warning light connection : 24Vac max 3 W
Courtesy light connection: 230 Vac max 200 W
Maximum power to be controlled at the motor connection : 700 W
Working time setting : min 5" , max. 120 "
Pause time setting min. 5", max. 120 ".
-
ON.