GB
4. Technical specifications
Operating voltage 950 JRM
Fusing the supply lines
PHC supply voltage for compact system (integrated)
Motor load per output
Power consumption
Input resistance
Contact resistance when activating inputs
Input signals
Max. length of 24V signal line
Conductor cross–section of 230V lines
Surrounding temperature
Storage temperature
Test specifications
Certifications
Degree of protection
Dimensions
230 V~ /50 Hz
Max. 10A overload release
Nom. 24 V DC (SELV), 21-28 V DC (ripple voltage 5%)
230V/50Hz max. 1A
approx. 0.7-4.5W (after input wiring)
1 kΩ
Max. 33 Ohm (corresponds to < 1V DC at 24 mA)
> 40ms
400m at d = 0.8 mm, Stripped length = 8 mm
1 x 1.5 mm² or 1 x 2.5 mm², Stripped length = 8 mm
+10° to +40°C
-20° to +60°C
EN 60669-2-1
CE
IP20
width
= 216mm (12TE), height
= 55mm
Technical specifications
Version number:
There is a label with the version
number on the 950 JRM.
119ROC2.4
2.4 = Version number
firmware
GB - 17