2.10 Input function priorities

Input function
Priority
Wind-/ rain sensor
0
Button UP/DOWN
1
Twilight sensor
2
Sun sensor
3
The wind/rain sensor has highest priority. Signals transmitted by lower priority sensors or button activations are ignored.
Button activation terminates all input functions with lower priority.
A "Twilight sensor" input function terminates all input functions with lower priority.
The sun sensor has the lowest priority. A signal transmitted by higher priority sensor or button activation terminates the
"Sun sensor" input function on all assigned motors.