Service information
Before returning your amplifier for service, please check the
following:
Sound cuts out for no reason
If the temperature of the internal heatsink rises above a safe
level, then a thermal cutout inside the amplifier will operate.
The power indicator on the front panel flashes and the
protection system temporarily removes the power to the
speakers. The system resets after the heatsink has cooled
down.
Technical specifications
Continuous power output, per channel
Both channels, 8Ω, 20Hz–20kHz
Single channel, 4Ω, 1kHz
Distortion, 8Ω, 80% power, 1kHz
Inputs
Phono cartridge input sensitivity, MM
Line and tape inputs:
Preamplifier outputs
Nominal output level
Output impedance
General
Power consumption (maximum)
Dimensions W x D x H (including feet)
Weight (net)
Weight (packed)
Supplied accessories
E&OE
Continual improvement policy
Arcam has a policy of continual improvement for its products.
This means that designs and specifications are subject to
change without notice.
Nominal sensitivity
Input impedance
Signal/noise ratio (CCIR)
Note that because of the high output voltage from a CD player,
it is possible to drive the A80 at full power even though the
volume is not set at maximum.
Amplifier does not switch back on
The A80 and P80 amplifiers have a protection mechanism
which is activated if you switch the unit on immediately after
turning it off. If this mechanism activates, wait 30 seconds then
switch back on again.
A80
65W
105W
0.005%
2.5mV
250mV
22kΩ
98dB
700mV
<50Ω
650VA
430 x 330 x 75mm
9kg
10kg
mains lead
CR-389 remote control
2 x AAA batteries
NOTE: All specification values are typical unless otherwise
stated.
P80
65W
105W
0.005%
700mV
22kΩ
108dB
650VA
430 x 330 x 75mm
9kg
10kg
mains lead
A80/P80
13