12. RESET
WARNING: This procedure restores the factory settings of the device. This procedure must be carried out by qualified technical personnel. Once the "reset" is
performed, the technician must install this device again (following the procedure on section 04) and verify proper operation.
12.1 USING A TRANSMITTER
ARCO
01. Bring the motor in an intermediate position.
02. Press MENU for about 5 sec, until «rS»
appears on display
03. Press 2 time PREV / 9 times NEXT.
«29» appears on display
04. Press STOP. The display flashes, the
motor performs some movement
05. Press together PREV and NEXT for about
2 seconds until the motor indicates that the
reset was performed (1 moving up / down).
06. Reinstall the motor (see section 4).
12.2 USING COMMAND BUTTONS
01. If possible, bring the motor to the intermediate position.
02. Disconnect the power supply.
03. Connect as on the diagram.
04. Connect the power supply. Wait 30 seconds, the motor makes a signal: «
05. Disconnect the power supply.
06. Restore the connections (see diagram on section 3).
07. Reinstall the motor (see section 4).
WARNING:
if the motor is reset near the upper limit switch or near the hooks, the signal may be different from that indicated
13. COMPATIBILITY WITH RADIO SENSORS
The presence of hooking systems is incompatible with automatic commands. Therefore:
If the motor is installed as "MANUAL HOOKS", the storage of radio sensors is prohibited.
If the motor is installed as "AUTOMATIC HOOKS" or "KLIVER MOTORIZED HOOKS" the storage of radio sensors is allowed but not recommended.
The sensors generate automatic maneuvers without warning that may be a source of danger. It is up to the installer to inform the end user and eventually integrate appropriate security
systems into the installation. In some situations (for example loss of motor voltage or sensor voltage, motor or sensor failure, radio noise ...) it is possible that the command given by
the sensor is not detected by the motor. The sensor must not therefore be considered as a safety device able to guarantee the integrity of the awning in all conditions, but a means to
reduce the probability of the blind being damaged by adverse weather events.
Use BLAST or BLAST BT or SHAKE (wind sensor), VEGA or VEGA BT (sun / wind sensor), THANK YOU (sun sensor), X11C (rain sensor) associated with the power supply At12 .
When the sensor detects the presence of wind, the message "wind alarm" is sent, the tuned motors moves upwards and the manual controls are inhibited until the end of the alarm.
When the sensor detects the sun, the message «sun present» is sent, the tuned motors moves downwards. When the sensor detects absence of the sun, the message «sun absent»
is sent, the tuned motors moves upward. When the sensor detects rain, the message «rain» is sent, the tuned motors are operated up or down, depending on the setting on the rain
sensor. Each motor can store up to 4 wind sensors, 1 sun sensor only. For more information, consult the sensor manual..
14. TEST RADIO
When a wind or sun / wind sensor is stored in the motor, a communication check between the radio sensor and the motor
is automatically activated. If communication is lost for more than 120 minutes, the motor performs an upward maneuver
to protect the awning. This automatic operation is performed every 120 minutes until the radio communication is
restored. The factory recommends keeping the "radio test" active in order to detect any malfunctions of the radio sensor
in good time.
To change this parameter:
10.1 UTILIZZANDO IL TRASMETTITORE (solo Atom e Leg)
ARCO
01. Bring the motor in an intermediate position
02. Press MENU for about 5 sec, until «rS»
appears on display
03. Press 1 time PREV / 7 times NEXT.
«17» appears on display
04. Press STOP. The motor signals:
see table
05. To activate: press PREV
To deactivate: press NEXT
06. Press STOP. The motor signals:
see table
15. OPERATING LOGIC OF COMMAND BUTTONS
The buttons can be operated either in PULSE logic or HOLD-TO-RUN logic.
PULSE: to activate the motor press a button for at least 0.5 seconds, to stop the motor press briefly (less than 0.5
seconds) one of the two buttons.
HOLD-TO-RUN: to activate the motor press a button for at least 0.5 seconds, to stop the motor release the button.
The factory sets the device to work in PULSE logic.
ATTENTION: when you are executing an hold-to-run command and a radio command intervenes, the motor stops a
hold-to-run command and executes the new maneuver: the radio command has priority.
10.1 UTILIZZANDO IL TRASMETTITORE (solo Atom e Leg)
ARCO
01. Bring the motor in an intermediate position
02. Press MENU for about 5 sec, until «rS»
appears on display
03. Press 1 time PREV / 8 times NEXT.
«18» appears on display
04. Press STOP. The motor signals:
see table
05. To select PULSE: press PREV
To select HOLD-TO-RUN: press NEXT
06. Press STOP. The motor signals:
see table
FLUTE, KUADRO, KORT
01. Bring the motor in an intermediate position.
02. Holding down STOP, press PROG for
about 1 sec, until LEDs light
03. Press 2 time UP / 9 times DOWN.
04. Press STOP. The LEDs flash, the motor
performs some movement
05. Press together UP and DOWN for about 2
seconds until the motor indicates that the
reset was performed (1 moving up /
down).
06. Reinstall the motor (see section 4).
Reset done
FLUTE, KUADRO, KORT
01. Bring the motor in an intermediate position
02. Holding down STOP, press PROG for
about 1 sec, until LEDs light
03. Press 1 time UP / 7 times DOWN.
04. Press STOP. The motor signals:
see table
05. To activate: press PREV
To deactivate: press NEXT
06. Press STOP. The motor signals:
see table
FLUTE, KUADRO, KORT
01. Bring the motor in an intermediate position
02. Holding down STOP, press PROG for
about 1 sec, until LEDs light
03. Press 1 time UP / 8 times DOWN.
04. Press STOP. The motor signals:
see table
05. To select PULSE: press DOWN
To select HOLD-TO-RUN: press UP
06. Press STOP. The motor signals:
see table
VISIO
01. Bring the motor in an intermediate position.
02. Press MENU, «Menu rx» appears on
display
03. Press 2 time PREV / 9 times NEXT.
«29» appears on display
04. Press STOP. The display flashes, the
motor performs some movement
05. Press together PREV and NEXT for about
2 seconds until the motor indicates that
the reset was performed (1 moving up /
down).
06. Reinstall the motor (see section 4).
5 poles
».
cable
*
factory setting
VISIO
01. Bring the motor in an intermediate position
02. Press MENU, «Menu rx» appears on
display
03. Press 1 time PREV / 7 times NEXT.
«17» appears on display
04. Press STOP. The motor signals:
see table
05. To activate: press PREV
To deactivate: press NEXT
06. Press STOP. The motor signals:
see table
Number of movements
* factory setting
VISIO
01. Bring the motor in an intermediate position
02. Press MENU, «Menu rx» appears on
display
03. Press 1 time PREV / 8 times NEXT.
«18» appears on display
04. Press STOP. The motor signals:
see table
05. To select PULSE: press DOWN
To select HOLD-TO-RUN: press UP
06. Press STOP. The motor signals:
see table
09
Other transmitters...
See the User manual of
the transmitter at
«RECEIVER MENU -
Function 29»
gray
black
brown
azule
yellow/green
N° of movements
1
Not active
*
2
Other transmitters...
See the User manual of
the transmitter at
«RECEIVER MENU -
Function 17»
Setting
*
Pulse
1
2
Hold-to-run
Other transmitters...
See the User manual of
the transmitter at
«RECEIVER MENU -
Function 18»
section:
Setting
Active
section:
section: