Moteurs tubulaires 45 mm avec fin de course électronique

Publicité

Les langues disponibles
  • FR

Les langues disponibles

06.2 «MANUAL HOOKS» MODE
NOTE: before starting the installation procedure, make sure that the manual hooks are disengaged.
Connect the power supply.
1-
Press PROG briefly (within 1 minute).
2-
The motor makes a signal
Press briefly UP.
3-
If the motor moves downward return to point 2,
if the motor moves upward go to point 4.
Bring the drop awning in an intermediate position,
4-
keeping pressed UP or DOWN.
Press STOP briefly 3 times and wait.
5-
The motor starts to make briefly upward movements...
After the
SECOND MOVEMENT
6-
The motor moves downward...
The motor (
7-
if mount with offset adapter
bar reaches the lower limit; otherwise press STOP to stop the motor in
the desired position.
If you want to adjust the position more precisely, see the "Fine
adjustment of the limit switches" box, otherwise wait about 10 s.
The motor moves upward. If the installation has a mechanical stop
8-
(recommended), go to step 9, otherwise go to step 10.
Upper limit switch by "pressure" (recommended):
9-
wait for the terminal to rest against the stop.
Motor makes a short downward movement. Installation completed !!
Manual upper limit switch:
10-
press STOP to stop the motor in the desired position.
If you want to adjust the position more precisely, see the "Fine
adjustment of the limit switches" box, otherwise wait about 10 s.
The motor makes a signal. Installation completed !!
Fine adjustment of the limit switches
Press PROG briefly, press UP or DOWN to move the motor
step-by-step, once you have reached the exact position,
press PROG briefly.
CAUTION:
During normal operation, the motor may go slightly below the automatically set lower limit switch to facilitate the insertion of
the hooks.
press briefly STOP.
) stops automatically when terminal
05
ON
Prog
3x
only if the offset
adapter is NOT
mounted
Prog
Go to point 4
Return to point 2
Prog