Re-fi tting covers - Antenna orientation
- Position the aerial and fi t the covers.
* To ensure proper remote control range, the
aerial must be fi tted in one of the two positions
shown beside.
10
Troubleshooting
Operating codes displayed
CODE
DESCRIPTION
Waiting for a command
C1
Door opening
C2
Waiting for the door to close
C3
Door closing
C4
Obstacle detection
C5
Safety input active
C6
Pedestrian door safety contact active
C9
Safety mechanism self test
Ca
Permanent hardwired control
Cb
Working from back-up battery
Cd
Waiting for a command
Programming codes displayed
CODE
DESCRIPTION
Awaiting setting
S1
Learning mode
S2
Awaiting remote control memorisation for
F0
operation in total opening
Awaiting remote control memorisation for
F1
operation in partial opening
Error and failure codes displayed
CODE
DESCRIPTION
Safety input always active
E2
Safety mechanism self test fault
E4
Other faults and failure conditions
Eb
Ec
Accessing stored data
To access stored data, select the "Ud" setting then press "OK"
CODE
DESCRIPTION
Total cycle counter: tens and units
U0
Total cycle counter: thousands and hundreds
U1
Total cycle counter: hundreds of thousands
U2
Cycle counter with obstacle detection: tens and units
U3
Cycle counter with obstacle detection: thousands
U4
Number of control channels memorised
U5
d0 à d9 Log of the last ten faults
Clears the fault log: press "OK" for 7 s.
dd
12
COMMENTS
Displayed during obstacle detection then for 30 s.
Displayed after a movement request or during movement, when the safety input is active.
This display is maintained as long as the safety input is active.
Displayed after a movement request or during movement, when the pedestrian door contact is open.
The display is maintained as long as the pedestrian door contact remains open.
Displayed during safety mechanism self tests.
Indicates that the permanent hardwired control input is activated (contact closed). Commands from radio
remote control units are inhibited.
COMMENTS
Pressing the "SET" button for 2 s starts the learning mode.
Pressing the "OK" button starts the learning cycle: the S2 display blinks during the entire cycle.
Pressing the "+" or "-" buttons will control the motor in forced mode.
Pressing a button on the remote control allocates this button to the motor total opening control.
Pressing "PROG" once more switches to "awaiting remote control memorisation for operation in partial opening: F1" mode.
Pressing a button on the remote control allocates this button to the motor partial opening control.
Pressing "PROG" once more switches to "awaiting remotely controlled lighting memorisation: F2" mode
COMMENTS
Displayed when the safety input
remains active for more than three
minutes.
The safety device self test failed
These codes correspond to various
electronic circuit board failures.
*
1
3
ACTION REQUIRED :
Check that there is no obstacle triggering cell or sensor bar detection.
Check that "P2" is setup correctly depending on the devices connected to the safety input.
Check safety device wiring.
When photoelectric cells are used, check their proper alignment.
VCheck that "P2" is setup correctly depending on the devices connected to the safety input.
Check safety device wiring.
When photoelectric cells are used, check their proper alignment.
Cut the power supply (mains & battery back-up), wait for a few minutes then re-connect the
power supply. Perform a learning cycle.
If the fault persists, contact SIMU Technical Support.