Checking the chain or belt tension
- The rails are supplied ready tensioned and inspected. If necessary, adjust the ten-
sioning.
The rubber or tension spring must never be full compressed during operation.
Connecting the mains power supply
1- Remove the motor cover and the protective sheet.
3- Fit the light bulb.
4- Connect to the mains supply.
Plug the power cable into a suitable power outlet that complies with electric power requirements. The electric supply must be
suitably protected (a fuse or circuit breaker with a 5 A rating) and a residual current device (30 mA).
An omnipolar disconnection mechanism must be provided for the power supply:
- by using a power cord with a mains splug that can be disconnected, or
- by fi tting a switch that ensures a contact separation distance of at least 3 mm for each pole (refer to standard EN60335-1).
Make sure that the manual release cord is located at a maximum height of 1.80 metres off the ground. If necessary, extend the cord.
5
Setting and programming
Programming keyboard description
starts self learning cycle
validation of selected parameter
validation of parameter value
parameter selection
1
Modifying a setting value
Controls the "forced mode"
17 mm
2
Press for 0.5 s: call up and exit the setup menu
Press for 2 s: start self-learning
Press for 7 s: clear self-learning and settings. Stop self-learning
Press for 2 s: memorise remote controls
ress for 7 s: delete remote controls
18 < X < 20 mm
3
7