4. Taking into operation
Before commissioning the information provided on the rating plate and in these instructions is to be observed. Non- obser-
vance can lead to the destruction of the beacon and to the jeopardising of safety.
The light is designed to be connected to permanent connection cables. The cable screw connections are suitable for cables
and lines installed in a stationary arrangement.
After connecting it to the power supply and fi xing/tightening the hood in place, the multifunction light is ready for operation. A
subsequent test is made to ensure satisfactory functional integrity.
Caution: In order to avoid damage to eyesight, please refrain from looking at the light for any length of time when it is in op-
eration.
X2
External control input
Reverse voltage protection!
No function when polarity is reversed.
S1
Operation
mode
1
2
3
OFF OFF OFF
1
OFF OFF
ON
2
OFF
ON
OFF
3
ON ON
OFF
4
ON
OFF OFF
5
ON
OFF
ON
6
ON ON
OFF
7
ON ON ON
8
Position of S1.4 = ON when using external control
4. Maintenance, Service and Ordering Spare Parts
The multifunction light is maintenance-free.
The polycarbonate housing may only be cleaned with water and a mild detergent solution.
As a principle, repairs are to be carried out at the manufacturer's factory. Parts (only use original spare parts) can be replaced
by suitably qualifi ed personnel.
085 501 980c
S1
1
2
3
4
Selection of operation mode
Switching through C1 to
operation mode no. ...
Standby for external
control
Flashing light 1 Hz
Continuous light
Blinking light 1 Hz
Flashing light 2 Hz
Blinking light 2 Hz
Flashing light 0,1 Hz
Flashing light 0,5 Hz
Example for selection via C1
Control of light intensity
Switching through C2
to operation mode no..
3
6
--
--
7
8
--
--
X2
X1
C1 C1 C2 C2
1 2 3 4
+
-
4
X1
Connection terminal
1 2 3 4
-
+
Wire connection
Switching through C1
+ C2 to operation mode
2
--
4
--
6
--
8
--
no. ..
4
6
4
--
8
8
8
--
30084-004-9c