GB
1
629 (WITH WOOD PAneLs)
PrePArInG THe PLInTH
Make certain the supporting surface is perfectly
level.
If the minipool is installed in the open (e.g. on a
lawn), prepare the plinth or slab with a suitably solid
foundation that will ensure the requisite stability.
ROOM VENTILATION
If the minipool is installed indoors, the room or enclo-
sure must be properly ventilated.
2
PERMANENT CONNECTION OPTIONS
PLUMBING CONNECTIONS
O
- ø 40 mm drain outlet connection
(for fixed installation only - optional)
- Cable outlet for connection to a.c. supply
EMPTYING
The tub can be emptied simply by connecting a
hose to the valve, or alternatively, by making a
permanent connection to the main drain (O). In this
instance it will be advisable to install a trap with
valve, which will serve as the foot valve.
IMPORTANT: before making any permanent
connection to the main drain, contact the local
authorities to check on regulations governing
the disposal of chemically treated water.
FILLING
The recommended method of filling the Teuco
minipool is to use a hose, taking care not to
immerse the end as this could allow reflux of water
back into the main.
IMPORTANT: if the intention is to connect the
minipool permanently to the water supply,
s u i t a b l e n o n - r e t u r n d e v i c e s m u s t b e
incorporated to prevent reflux back to the water
main.
Contact the local authorities before proceeding
with this type of installation.
10
PRE-INSTALLATION Art. 629
ELECTRICAL CONNECTIONS
The electrical power supply must be in compliance
with statutory regulations for the country of
installation.
The product must be connected to the mains power
via an omnipolar switch (I) with an opening between
contacts that guarantees complete disconnection in
excess voltage category III conditions (minimum 3
mm), installed outside areas 0,1,2,3 (IEC 60364-7-
701).
Make certain the appliance is connected to the
power source by way of a residual current device
with minimum threshold 30mA.
The connection must include a connection to the
earth system and must be:
- permanent
- able to handle the rated current (see data plate)
- specified to liquids ingress protection category IPX5
PANELLED MINIPOOL (IEC 364-7-701)
ZONA 1
ZONA 2
ZONA 0
ZONA 0
1,5 m
2 m
= h
ZONA 2
2 m
1,5 m