Scope of delivery
5
Scope of delivery
GF
Moving leaf
SF
Fixed leaf
1
ISM Moving-leaf guide rail
2
ISM Fixed-leaf guide rail
3
Smoke switch (packed)
4
Electrical hold-open device
for moving leaf
5
Electrical hold-open device
for fixed leaf
6
Mounting and securing
6. 1
Drilling template
TS 5000 L with R-ISM guide rail for direct fixing or fixing with a mounting plate.
±0,2
784,5
763,5
±0,2
440
±0,2
367,5
140
110
135
±0,2
±0,2
160
784,5
±0,2
±0,2
763,5
367,5
140
440
±0,2
122
±1
±0,2
160
A
Bore for smoke switch housing
B
Ø 15 mm, Power supply (230 V AC)
GB 3
6
7
8
9
10
11
12
13
14
±0,2
440
±0,2
135
±0,2
B
C
A
±0,2
160
±0,2
±0,2
440
±0,2
160
B
C
A
Wire cable for trigger
Trigger
Sliding lever
Power pack with mounting
End cap
Moving-leaf cover panel
Fixed-leaf cover panel
Middle cover panel
Inspection cap
±0,2
140
140
440
110
110
135
±0,2
±0,2
160
140
140
±0,2
440
±0,2
122
±1
122
±1
160
C
Ø 15 mm, Opening for additional connections
(optional)
TS 5000 R-ISM BG
Fig.: 5.1
15
Protective cap
16
Foam lining
17
Smoke switch housing
18
Reset button
19
Sliding block
20
Wire cable redirection
21
Trigger lever
Screws, fitting template and
accessories bag (without illustration)
784,5
±0,2
763,5
±0,2
±0,2
367,5
440
±0,2
135
A
C
B
160
784,5
±0,2
763,5
±0,2
367,5
±0,2
±0,2
440
160
A
C
B
Fig.: 6.1.1
140
110
±0,2
±0,2
140
±0,2
122
±1