19
TROUBLE SHOOTING
Danger due to electrical voltage! Manipulating the machine with the power supply
up can lead to serious injuries or death. Always disconnect the machine from the
power supply before carrying out any troubleshooting work!
Many possible sources of error can be excluded in advance if the machine is properly connected
to the mains.
If you are unable to carry out necessary repairs properly and/or do not have the required
training, always consult a specialist to correct/solve the problem!
Trouble
Motor does not run
Workpiece kick-back
Blade does not reach the
necessary speed
Machine vibrates heavily
HOLZMANN MASCHINEN GmbH
W A R N I N G
Possible cause
ON-OFF-switch defect
Motor defect
No power supply
Fuse or protection defect
Extention cord damaged
Dull saw blade
Wrong assembled saw blade
Extention cord to long
Weak power grid
Uneven surface
Motor mount loose
www.holzmann-maschinen.at
TROUBLE SHOOTING
Solution
Repair switch
Exchange motor
Connect to mains
Change fuse
Activate protection
Change
Replace saw blade
Check direction / assemble
Change
Contact power suppliers
Reconstitute
Fix motor mount
42
TK 305